INSTALLATION
Install and tighten the O
sensor to the cylinder head
2
to the specified torque.
TORQUE: 25 N·m (2.5 kgf·m, 18 lbf·ft)
Connect the O
sensor cap by installing a new O
2
sensor cord between the wire guide legs.
• Take care not to tilt the O
necting the cap to the O
• Do not turn the O
sensor cap, after connecting it.
2
Connect the O
sensor 2P connector.
2
After installation, make sure the exhaust gas does
not leak.
Install the following:
– Floor panel side cover (page 3-5)
– Luggage box (page 3-8)
FUEL SYSTEM (Programmed Fuel Injection)
2
sensor cap when con-
2
sensor.
2
O
WIRE GUIDE LEGS
O
SENSOR
2
O
CORD
O
SENSOR 2P CONNECTOR
2
SENSOR
2
O
SENSOR CAP
2
SENSOR
2
6-55