Configuration Commands; Read And Write Parameters - Pepperl+Fuchs IDENTControl IQH3-FP-V1 Manual

Rfid read/write device
Table of Contents

Advertisement

IQH3-FP-V1
Operation
Example
S#100050002Z fills from address 0005 to 0007 with fill sign Z
Note
If <NumOfWords> is set to 0000, the read/write tag is filled to the end of the read/write tag from
<WordAddr> onward.
6.7

Configuration Commands

The response to a configuration command is a status message from the read/write device.
During the read operation, a status message and the corresponding data are received as the
response.
6.7.1

Read and Write Parameters

With the read parameter RP and write parameter WP configuration commands, you can
read/write the following parameters:
Parameter
Abbrevi-
ation
CT
DR
E5
IF
NT
OH
PT
QV
QW
RD
TA
ST
TE
TI
TO
The parameters are saved in the read/write device as nonvolatile.
Read Parameters
The RP command reads configuration parameters from the read/write device.
Command:
Response:
Page
See "Change Tag CT" on page 28
See "Data Rate DR" on page 28
See "Enhanced Status 5 E5" on page 29 Readable/writeable 5
See "IF Information" on page 29
See "Number of Tags to Find NT" on
page 30
See "Operating Hours OH" on page 30
See "Power Transmit PT" on page 31
See "Protocol Mode QV" on page 31
See "Q Value QW" on page 32
See "Reset to Default RD" on page 32
See "Tries Allowed TA" on page 33
See "Status Frontend ST" on page 33
See "Temperature TE" on page 34
See "Tag ID Filter TI" on page 34
See "Excess Temperature Handling TO"
on page 34
RP <SystemCode> <ParamTyp> <DataLength> <Data> <CHCK> <ETX>
<Status> <Data> <CHCK> <ETX>
.
ASCII
Parameter
Default value
Readable/writeable 20 = mixed opera-
tion
Readable/writeable 0 = normal
Readable/writeable 0 = off
Readable/writeable 255 = off
Readable
-
Readable/writeable 4 = Power
Readable/writeable S = single-frame
protocol
Readable/writeable 0 = one tag
Writeable
-
Readable/writeable 2 = two attempts
Readable
-
Readable
-
Readable/writeable -
Readable/writeable 0 = off