Pepperl+Fuchs IDENTControl IQH3-FP-V1 Manual page 32

Rfid read/write device
Table of Contents

Advertisement

IQH3-FP-V1
Operation
Meaning of the bytes in response .30.31.00.02
.30
.31
.00
.02
Temperature TE
The TE parameter allows you to read internal read/write device temperatures.
ParamTyp:
Response to an RP command of the TE parameter:
<Status> <ChanNo> <Tpa> <Tµc> <CHCK> <ETX>
<Tpa>
<Tµc>
Example
RP1QTE.00.00 reads out the internal read/write device temperatures.
Meaning of the bytes in response .30.31.20.21
.30
.31
.20
.21
Tag ID Filter TI
You can use the TI parameter to filter tags using the UID. Read/write commands are executed
on tags with an UID that matches the filter. You can set the filter to the entire UID or to the lead-
ing bytes.
ParamTyp:
Value range:
Example
WP1QTI.00.04.E0.08.01.48 sets the filter to tags with a UID beginning with the 4 bytes
E0.08.01.48.
RP1QTI.00.00 reads out the current filter.
34
Status 0
, command has been executed successfully
ASCII
1
, IDENTControl channel 1
ASCII
No message
Coil detuning due to metal
TE
Temperature in °C at the power amplifier, 1 byte
Temperature in °C at the microcontroller, 1 byte
Status 0
, command has been executed successfully
ASCII
1
, IDENTControl channel 1
ASCII
32
°C at the power amplifier
dec
33
°C at the microcontroller
dec
TI
0 – 8-byte UID