IQH3-FP-V1
Operation
Abbrevia-
tion
ER
SW
EW
SL
EL
S#
SG
EG
SC
EC
Configuration commands
Abbrevia-
tion
RP
WP
6.6
Read/Write Commands
Single Read Read-Only Code SF
The read/write device makes one attempt to read a read-only code.
Command:
Response:
Enhanced Buffered Read Read-Only Code EF
The read/write device makes continuous attempts to read a read-only code. If a read-only code
is read, this is reported once.
A status 5 message is sent when a tag leaves the sensing range.
Command:
Response:
Single Read Words SR
The read/write device makes one attempt to read <WordNum> 32-bit words from the address
<WordAddr> onward.
Command:
Response:
Enhanced Buffered Read Words ER
The read/write device continuously attempts to read <WordNum> 32-bit words from the
address <WordAddr> onward. Only changing data is transferred via the interface.
A status 5 message is sent when a tag leaves the sensing range.
Command description
See "Enhanced Buffered Read Words ER" on page 23
See "Single Write Words SW" on page 24
See "Enhanced Buffered Write Words EW" on page 24
See "Single Write Words with Lock SL" on page 24
See "Enhanced Write Words with Lock EL" on page 24
See "Fill Datacarrier S#" on page 26
See "Single Get Configuration SG" on page 24
See "Enhanced Get Configuration EG" on page 25
See "Single Set Configuration SC" on page 26
See "Enhanced Set Configuration EC" on page 26
Command description
See "Read Parameters" on page 27
See "Write Parameters" on page 28
SF <ChanNo> <CHCK> <ETX>
<Status> <ChanNo> <Data> <CHCK> <ETX>
EF <ChanNo> <CHCK> <ETX>
<Status> <ChanNo> <Data> <CHCK> <ETX>
SR <ChanNo> <WordAddr> <WordNum> <CHCK> <ETX>
<Status> <ChanNo> <Data> <CHCK> <ETX>
23