OBD10M-R2000-4EP-V1V17

Commissioning

5
Commissioning
1.
Connect the device to the power supply.
The initialization phase lasts approx. 10 seconds. This phase is indicated by
an illuminated Power LED. The display is still disabled in this phase.
2.
There is another initialization phase that lasts approx. 10 seconds.
The display turns on and shows circles moving downward.
3.
After the initialization phase, the Pepperl+Fuchs logo will appear.
The device is ready for operation.
To achieve the best measurement accuracy, allow the device to warm up for 30
minutes.
The sensor has been tested and calibrated before delivery. It can be put into oper-
ation immediately.
It is generally recommended to use a dedicated network card for the connection
to the device.
For parameterization, connect the device to an Ethernet interface on a computer.
Install the PACTware software and the appropriate DTM.
5.1

Ethernet Configuration

The sensor has three different addressing options that can be used as required.
The setting is configured using the menu interface on the sensor itself.
Auto IP
In the Auto IP setting, the sensor independently assigns a "link-local" IP address
in the 169.254.0.0/16 range. During this process, the system ensures that the
selected address is not already being used by another device.
Configuring a Connection via Auto IP
The sensor is set to Auto IP by default. The Auto IP setting is the best way to con-
nect directly to a PC.
1.
If the network configuration of the sensor no longer matches the factory setting:
1.
2. Restart the sensor to apply the configuration.
3.
To connect the sensor to the PC, set the PC to Dynamic Host Configuration
Protocol (DHCP).
4.
Adjust the properties of the PC network card accordingly. To do this, select the
TCP/IP protocol in the network card properties.
5.
In the Internet protocol properties, select Obtain an IP address automatically.
Under Ethernet Setup > Address Mode, set the sensor to "Auto IP."