Operation
[<Data 12> VICC memory size, number of blocks -1]
[<Data 13> VICC memory size, block size in bytes - 1]
[<Data 14> IC reference]
Single Set Configuration SC
The read/write device makes precisely one attempt to write the AFI or DSFID.
If the AFI or DSFID is already read-only, a rewrite or write-protect operation has a response with
status 5.
Command:
Response:
<ConfAddr> = 30
<Data 1> = Lock of the AFI; 00
<Data 2> = AFI value
<Data 3> = not used; 00
<Data 4> = not used; 00
Example
SC100900 writes the AFI to channel 1 with 39 hex without lock.
Enhanced Set Configuration EC
The read/write head makes continuous attempts to write the AFI or DSFID.
If the AFI or DSFID is already read-only, a rewrite or write-protect operation has a response with
status 5.
Command:
Response:
<ConfAddr> = 30
<Data 1> = Lock of the AFI; 00
<Data 2> = AFI value
<Data 3> = not used; 00
<Data 4> = not used; 00
Fill Datacarrier S#
The word number <WordNum> of fill signs <Fill Sign> is written to the read/write tag from the
specified start address <WordAddr>.
Command:
Response:
1. <NumOfWords> = 4 ASCII characters
26
2<Default ¬¹ Font>
SC <ChanNo> <ConfAddr> <Data 1> <Data 2> <Data 3> <Data 4>
<CHCK> <ETX>
<Status> <ChanNo> <CHCK> <ETX>
= '0' (Write AFI and Lock AFI); 31
hex
/ 30
without lock AFI, 01
hex
hex
hex
hex
EC <ChanNo> <ConfAddr> <Data 1> <Data 2> <Data 3> <Data 4>
<CHCK> <ETX>
<Status> <ChanNo> <CHCK> <ETX>
= '0' (Write AFI and Lock AFI); 31
hex
/ 30
without lock AFI, 01
hex
hex
hex
hex
S# <ChanNo> <WordAddr> <NumOfWords>
<Status> <ChanNo> <CHCK> <ETX>
2<Default ¬¹ Font>
2<Default ¬¹ Font>
= '1' (Write DSFID and Lock DSFID)
hex
/ 31
with lock AFI
hex
hex
= '1' (Write DSFID and Lock DSFID)
hex
/ 31
with lock AFI
hex
hex
1
<Fill Sign> <CHCK> <ETX>