  • Page 1 IDM-Z1-161-M-1D-J1-BT-N-N0 IDM-Z1-161-M-1D-J1-BT-P-N0 IDM-Z1-261-M-2D-J1-BT-N-N0 Bluetooth handheld scanner for use in explosion- hazardous areas Zone 1/21 Manual...
  • Page 2 Phone: +49 621 776 - 0 E-mail: info@de.pepperl-fuchs.com North American Headquarters Pepperl+Fuchs Inc. 1600 Enterprise Parkway Twinsburg, Ohio 44087 Phone: +1 330 425-3555 E-mail: sales@us.pepperl-fuchs.com Asia Headquarters Pepperl+Fuchs Pte. Ltd. P+F Building 18 Ayer Rajah Crescent Singapore 139942 Phone: +65 6779-9091 E-mail: sales@sg.pepperl-fuchs.com https://www.pepperl-fuchs.com...
  • Page 3: Table Of Contents

    IDM-Z1-161-M-1D-J1-BT-N-N0, IDM-Z1-161-M-1D-J1-BT-P-N0, IDM-Z1-261-M-2D- J1-BT-N-N0 Safety .......................... 4 Introduction ....................4 1.1.1 Content of this Document ..............4 1.1.2 Manufacturer..................4 1.1.3 Target Group, Personnel ..............4 1.1.4 Symbols Used ................... 5 Technical Specifications ................... 6 Explosion Protection ..................6 Technical Data for Bluetooth Scanner ............7 Use ........................
  • Page 4: Safety

    IDM-Z1-161-M-1D-J1-BT-N-N0, IDM-Z1-161-M-1D-J1-BT-P-N0, IDM-Z1-261-M-2D- J1-BT-N-N0 Safety Introduction 1.1.1 Content of this Document This document contains information required to use the product in the relevant phases of the product life cycle. This may include information on the following: • Product identification •...
  • Page 5: Symbols Used

    IDM-Z1-161-M-1D-J1-BT-N-N0, IDM-Z1-161-M-1D-J1-BT-P-N0, IDM-Z1-261-M-2D- J1-BT-N-N0 1.1.4 Symbols Used This document contains symbols for the identification of warning messages and of informative messages. Warning Messages You will find warning messages, whenever dangers may arise from your actions. It is mandatory that you observe these warning messages for your personal safety and in order to avoid prop- erty damage.
  • Page 6: Technical Specifications

    IDM-Z1-161-M-1D-J1-BT-N-N0, IDM-Z1-161-M-1D-J1-BT-P-N0, IDM-Z1-261-M-2D- J1-BT-N-N0 Technical Specifications Explosion Protection 1D-Modelle: II 2G Ex ib IIB T4 Gb II 2D Ex ib IIIC T135°C Db 2D-Modelle: II 2G Ex ib op is IIB T4 Gb II 2D Ex ib op is IIIC T135°C Db...
  • Page 7: Technical Data For Bluetooth Scanner

    IDM-Z1-161-M-1D-J1-BT-N-N0, IDM-Z1-161-M-1D-J1-BT-P-N0, IDM-Z1-261-M-2D- J1-BT-N-N0 Technical Data for Bluetooth Scanner IDM-Z1-161-M-1D- IDM-Z1-161-M-1D- IDM-Z1-261-M-2D- J1-BT-N-N0 J1-BT-P-N0 J1-BT-N-N0 Description Linear imager 2-D imager Barcode One-dimensional 1-D One-dimensional 1-D One-dimensional 1-D (barcode) (Barcode and stacked & 2-D (Barcode and code incl. PDF417) stacked code incl.
  • Page 8 IDM-Z1-161-M-1D-J1-BT-N-N0, IDM-Z1-161-M-1D-J1-BT-P-N0, IDM-Z1-261-M-2D- J1-BT-N-N0 It enables portable recording and direct data transfer of barcodes and 2-D codes in explosion- hazardous areas. The device is specifically modified for use in explosion-hazardous areas of Zone 1 and Zone 21.
  • Page 9: System Structure

    IDM-Z1-161-M-1D-J1-BT-N-N0, IDM-Z1-161-M-1D-J1-BT-P-N0, IDM-Z1-261-M-2D- J1-BT-N-N0 SYSTEM STRUCTURE Overview The Bluetooth handheld scanners and their accessories are presented in the following over- view. Charging the handheld scanner batteries can take place within the hazardous area using the Zone 1/21 certified base station and the associated power module. Furthermore, the scan-...
  • Page 10 IDM-Z1-161-M-1D-J1-BT-N-N0, IDM-Z1-161-M-1D-J1-BT-P-N0, IDM-Z1-261-M-2D- J1-BT-N-N0 Figure 3.1 Handheld scanners and accessories In the following two chapters, the typical usage cases are described in more detail.
  • Page 11: System Structure 1

    IDM-Z1-161-M-1D-J1-BT-N-N0, IDM-Z1-161-M-1D-J1-BT-P-N0, IDM-Z1-261-M-2D- J1-BT-N-N0 System Structure 1 Charger & Base Station, RS232 connection to internal VisuNet GXP barrier Overview of the complete system structure 1: Bluetooth handheld scanners IDM-Z1-161-M- 1D-J1-BT-*, IDM-Z1-261-M-2D-J1-BT-N-N0, and base station connected to intrinsically safe RS232 Ex i interface VisuNet GXP.
  • Page 12 IDM-Z1-161-M-1D-J1-BT-N-N0, IDM-Z1-161-M-1D-J1-BT-P-N0, IDM-Z1-261-M-2D- J1-BT-N-N0 Figure 3.3 System structure 2 – scanner with base station connected to VisuNet GXP (Option 1) Description: The Bluetooth handheld scanner has been designed with the battery for explosion- hazardous areas. For proper operation in explosion-hazardous areas an IDM-Z1-x61- B-J1-BT-N0 base station, a CBL-IDM-Z1-x61-B-J1* cordset between the base station and the SK-IDM-Z1-160- BD-1D-J1* supply module, and a connection cable to the power supply are required.
  • Page 13: System Structure 3

    IDM-Z1-161-M-1D-J1-BT-N-N0, IDM-Z1-161-M-1D-J1-BT-P-N0, IDM-Z1-261-M-2D- J1-BT-N-N0 Figure 3.4 System structure 2 – scanner with base station connected to barrier (Option 2) Note The Supply module is available for RS232 and USB, make sure to use the compatible RS232 or USB cables. System Structure 3...
  • Page 14 IDM-Z1-161-M-1D-J1-BT-N-N0, IDM-Z1-161-M-1D-J1-BT-P-N0, IDM-Z1-261-M-2D- J1-BT-N-N0 Figure 3.5 System structure 3 - scanner with a base station in the safe area/Bluetooth option VisuNet Description: The Bluetooth handheld scanners can be used alone in explosion-hazardous areas; the base station and charging cradle can be installed in the safe area.
  • Page 15 IDM-Z1-161-M-1D-J1-BT-N-N0, IDM-Z1-161-M-1D-J1-BT-P-N0, IDM-Z1-261-M-2D- J1-BT-N-N0 Figure 3.6 PSU-IDMx61-BC-N0-N0 Non-Ex Power Supply needs to be connected to the SUB-D9 connector Figure 3.7 When USB 3.0 is available set the USB bus power switch to “ON”. Then connect the cradle and host device via an USB cable.
  • Page 16: Commissioning

    IDM-Z1-161-M-1D-J1-BT-N-N0, IDM-Z1-161-M-1D-J1-BT-P-N0, IDM-Z1-261-M-2D- J1-BT-N-N0 Commissioning Preparing Bluetooth Handheld Scanners Note Please charge the new battery pack for 8 hours prior to the first use Danger! The battery must not be changed or inserted in explosion-hazardous areas. Improper handling can void the type approval.
  • Page 17 IDM-Z1-161-M-1D-J1-BT-N-N0, IDM-Z1-161-M-1D-J1-BT-P-N0, IDM-Z1-261-M-2D- J1-BT-N-N0 Danger! The designated battery must only be used! The battery is inserted into the compartment on the handheld scanner. The end of the pull tab must be seen protruding out of the opening of the handheld scanner. If the battery is inserted correctly and connected to the contacts, there is an audible and visual signal.
  • Page 18 IDM-Z1-161-M-1D-J1-BT-N-N0, IDM-Z1-161-M-1D-J1-BT-P-N0, IDM-Z1-261-M-2D- J1-BT-N-N0 Figure 4.4 Connecting RJ50 connector of connection cable CBL-IDM* to base station Figure 4.5 Male M12 connector of connection cable CBL-IDM* Figure 4.6 Female M12 connector of pre-installed base connection cable of the supply module SK-...
  • Page 19 IDM-Z1-161-M-1D-J1-BT-N-N0, IDM-Z1-161-M-1D-J1-BT-P-N0, IDM-Z1-261-M-2D- J1-BT-N-N0 Figure 4.7 Connecting the plug coupling to the supply module basic connection line The handheld scanner is placed in the charger. The underside of the handle is used first to ensure that the charging contacts are properly connected. The LED light on the scanner head indicates successful charging.
  • Page 20 IDM-Z1-161-M-1D-J1-BT-N-N0, IDM-Z1-161-M-1D-J1-BT-P-N0, IDM-Z1-261-M-2D- J1-BT-N-N0 Figure 4.9 Connecting the power supply for the non-explosion-hazardous base station To connect in the non-explosion-protected area, the cable to connect to the power supply and to the PC is inserted into the opening for this at the bottom of the base station. An audible click can be heard when the cable is fully inserted.
  • Page 21: Pinout Of Supply Module With Rs232 Or Usb

    IDM-Z1-161-M-1D-J1-BT-N-N0, IDM-Z1-161-M-1D-J1-BT-P-N0, IDM-Z1-261-M-2D- J1-BT-N-N0 Figure 4.11 Inserting the scanner into the base station Pinout of Supply Module with RS232 or USB Supplying the base station according to system structure 2 via connector - plug/coupling. The terminal assignment is located under the unscrewable opening on the front of the supply module.
  • Page 22 IDM-Z1-161-M-1D-J1-BT-N-N0, IDM-Z1-161-M-1D-J1-BT-P-N0, IDM-Z1-261-M-2D- J1-BT-N-N0 Figure 4.12 Supply module terminal compartment External connection lines: Data lines USB: 0.2 – 2.5 mm , 4-core or RS232: 0.2 – 2.5 mm 3-core Supply line 0.2 – 2.5 mm 3-wire (see accessories in the appendix) The Bluetooth handheld scanner, the base station, and the supply module may be connected and used in explosion-hazardous areas.
  • Page 23: Base Connection Line Rs232

    IDM-Z1-161-M-1D-J1-BT-N-N0, IDM-Z1-161-M-1D-J1-BT-P-N0, IDM-Z1-261-M-2D- J1-BT-N-N0 Figure 4.14 Intrinsically safe terminal compartment of the supply module after removing the connector connection cores Base connection line RS232 Assignment of pre-installed base connection cable to supply module (RS232) Assignment of pre-assembled connec- tion coupling...
  • Page 24: Base Connection Line Usb

    IDM-Z1-161-M-1D-J1-BT-N-N0, IDM-Z1-161-M-1D-J1-BT-P-N0, IDM-Z1-261-M-2D- J1-BT-N-N0 Assignment of connection cable CBL-IDM-x61* to supply module (RS232) Cordset assignment Supply module terminal compartment RJ50 pinout Strand color Designation Assignment White Brown Yellow Note Information relating to programming from the SICK AG manual (www.SICK.com) is required for the complete commissioning of the handheld scanner.
  • Page 25 IDM-Z1-161-M-1D-J1-BT-N-N0, IDM-Z1-161-M-1D-J1-BT-P-N0, IDM-Z1-261-M-2D- J1-BT-N-N0 Direct connection of the base station without plug/coupling to the supply module with USB interface Figure 4.16 RJ50 plug - connection layout Base station cordset Cordset assignment Supply module terminal compartment RJ45 pinout Strand color Designation...
  • Page 26: Accessories

    IDM-Z1-161-M-1D-J1-BT-N-N0, IDM-Z1-161-M-1D-J1-BT-P-N0, IDM-Z1-261-M-2D- J1-BT-N-N0 Accessories Corded Handheld Reader Mounting Accessories Item num- Product name Description Photo #548267 SCANNER-HOLDER-U1- Scanner holder compatible with XX00-N0 Housing AG-XX00 Material: Stainless steel AISI 316L (1.4404) Compatible with IDMx6x, ecom IdentEx 01 and PSCAN Prepared for mounting to right side...
  • Page 27 IDM-Z1-161-M-1D-J1-BT-N-N0, IDM-Z1-161-M-1D-J1-BT-P-N0, IDM-Z1-261-M-2D- J1-BT-N-N0 Bluetooth Handheld Reader Accessories for VisuNet HMI Applications Item Num- Product Name Description Photo #70115390 IDM-Z1-x61-B-J1-BT-N0 Bluetooth reader base station & charger Ex-protection: ATEX&IECExZone 1Radio Interface: Bluetooth Protocol: USB/Serial (depends on connection cable) Compatible with IDM-Z1-x61-M...
  • Page 28 IDM-Z1-161-M-1D-J1-BT-N-N0, IDM-Z1-161-M-1D-J1-BT-P-N0, IDM-Z1-261-M-2D- J1-BT-N-N0 Bluetooth Handheld Reader Accessories for VisuNet HMI Applications Item Num- Product Name Description Cable Photo #548345 CBL-IDMx61-B- Serial connection cable for Straight N0-S-S18-N0 base station 1,8 m length Ex-protection: non-Ex, for use in safe area only!
  • Page 29 IDM-Z1-161-M-1D-J1-BT-N-N0, IDM-Z1-161-M-1D-J1-BT-P-N0, IDM-Z1-261-M-2D- J1-BT-N-N0 Item Num- Product Name Description Cable Photo #548349 CBL-IDMx61-B- Serial connection cable for Straight J1-S-S18-N0 base station 1,8 m length Ex-protection: suitable for Zone 1/21 & Zone 2/22 Interface: RJ50 (cradle) to M12 male connector Cable: straight; 1,8m...
  • Page 30 IDM-Z1-161-M-1D-J1-BT-N-N0, IDM-Z1-161-M-1D-J1-BT-P-N0, IDM-Z1-261-M-2D- J1-BT-N-N0 Serial extension cables Item Num- Product Name Description Cable Photo #548356 CBL-IDMx6x-DB- Serial extension cable Coiled J1-S-C30-N0 Ex-protection: suitable for 3 m length Zone 1/21 & Zone 2/22 Interface: M12 female socket to M12 malecon- nector...
  • Page 31 IDM-Z1-161-M-1D-J1-BT-N-N0, IDM-Z1-161-M-1D-J1-BT-P-N0, IDM-Z1-261-M-2D- J1-BT-N-N0 Corded Handheld Reader Accessories for VisuNet HMI Applications Ex-protection: ATEX&IECEx Zone 1/21 Item num- Product name Description Photo #70115393 SK-IDM-Z1-160-BD-1D- Barrier for corded 1D reader & base J1-DC-S-N station Input: 24 V DC Protocol: RS-232/422/485 Ex e (to...
  • Page 32 Pepperl+Fuchs Quality Download our latest policy here: www.pepperl-fuchs.com/quality www.pepperl-fuchs.com © Pepperl+Fuchs · Subject to modifications Printed in Germany / DOCT-6088A...

This manual is also suitable for:

Idm-z1-161-m-1d-j1-bt-p-n0Idm-z1-261-m-2d-j1-bt-n-n0

Table of Contents