14221-1800-2050, Rev. G

6.14.6 Custom Scan Lists

The Mixed Zone Scan (MZS) feature gives the user the capability to scan based on a custom
scan list that is assigned at the system level. The Custom Scan (CS) list can contain System and
Channel/Group configurations across P25 Trunked, P25 Conventional, and Analog Systems.
When a Custom Scan List is assigned to a P25T system, the radio can scan P25T, P25C and
Analog systems. When assigned to a P25C or Analog system, the radio only scans conventional
channels. MZS also gives the user the capability to scan beyond the selected system group set.
P25T Scan
When a custom scan list is assigned to a P25T system, the user can scan P25T, P25C, and
Analog groups/channels. All P25T systems must have the same WACN, System ID, and Unit
ID to be added to the custom scan list. If P25C and/or analog channels are added to the
custom scan list, the radio will scan them using the Trunked/Conventional scan feature
described in section 6.14.2, and will override any other conventional scan list that may have
been programmed using RPM2.
P25C and Analog Scan
When a custom scan list is assigned to a P25C or Analog System, the user can scan P25C
and Analog channels. P25T systems are ignored.
Custom scan list can be created using RPM2 or at the radio. The radio supports up to 10 Custom
Scan lists, with up to 100 channels/groups in each.
6.14.6.1 Create Custom Scan List
To create a custom scan list at the radio:
1. Press the Menu/Select button.
2. Press the left or right navigation buttons to display the SCAN menu.
3. Press the up or down navigation buttons to highlight ASSIGNED CUSTOM LIST and press
the Menu/Select button.
4. Press the OPTIONS softkey.
5. Select ADD SCAN LIST.