Save And Recall The Waveform - Promax OD-603 Manual

Digital oscilloscope
Table of Contents

Advertisement

3.5.3.1

Save and Recall the Waveform

The oscilloscope can store 15 waveforms, which can be displayed with the
current waveform at the same time. The stored waveform called out can not be
adjusted.
In order to save the waveform of the CH1 into the address 1, the operation steps
should be followed:
Saving: Press the H1 button, the Type menu will display at the left of
screen, turn the M knob to choose Wave for Type.
Press the H2 button and press F1 button to select CH1 for Source.
Press the H3 button and press the F1, turn the M knob to select 1 as
object address.
Press the H5 button and press F1 button to select Internal.
Press the H4 button to save the waveform.
Recalling: Press the H3 button, and press the F1, turn the M knob to
select 1 as object address. Press F2 button to set Show as ON. The
waveform stored in the address will be shown, the address number and
relevant information will be displayed at the top left of the screen.
June 2016
Figure 48. Wave Saving.