Teledyne Linea Color GigE LA-GC-02k05B User Manual page 59

Table of Contents

Advertisement

Example: Counter Start Source = CounterEnd (itself)
Countermode=OFF
Counter is
IDLE
CounterStartSource=
CounterEnd (itself)
Counter starts when Counter Mode is set to Active.
A Counter Reset CMD will reset the counter to 00 and it then continues counting.
counterResetSource must be set to CounterEnd. When the counterValue feature reaches the
counterDuration value an event is generated and the counter is reset to 00, then continues.
Example: CounterStartSource = EVENT and Signal (Edge Base)
Countermode=OFF
Counter is
IDLE
CounterStartSource= EVENT or
Signal (Edge Base )
Linea GigE Series Camera
CounterStartSource=CounterEnd (itself)
Countermode=Active
CounterWait
Trigger
Counter is incrementing
0
CounterStartSource= EVENT and Signal (Edge Base )
Countermode=Active
CounterWait
Trigger
Counter is incrementing
0
CounterEnd Event Generated
Counter is
Counter
Active
Completed
CounterEnd Event Generated
Counter is
Counter
Active
Completed
Counter Reset CMD
CounterResetSource=CounterEnd
Counter
Overflow
CounterResetSource=OFF
Counter Reset CMD
CounterResetSource=Event (Itself)
CounterResetSource=Event
CounterResetSource=CounterEnd(Itself)
Operational Reference • 57