Line Inverter
Input Line Debouncing
Period
Line Electrical Termination
Disabled
Enabled
Output Line Source
Off
Software Controlled
Pulse on: Start of Frame
Pulse on: Start of Line
Pulse on: Start of Exposure
Pulse on: End of Exposure
Pulse on: Start of Readout
Pulse on: End of Readout
Pulse on: Valid Line Trigger
Pulse on: Invalid Line
Trigger
Pulse on: Start of Acquisition
Pulse on: End of Acquisition
Pulse on: End of Timer 1
Pulse on: End of Timer 2
Pulse on: End of Counter 1
Pulse on: End of Counter 2
Pulse on: Input Line 1 Event
Pulse on: Input Line 2 Event
Pulse on: Input Line 3 Event
Pulse on: Input Line 4 Event
Pulse on: Rotary Encoder 1
Pulse on: Software
Command
Frame Trigger
Frame Valid
Exposure Active
Line Active
Smart Strobe Active
Linea GigE Series Camera
LineInverter
False / True
lineDebouncingPeriod
lineElectricalTermination
Disabled
Enabled
outputLineSource
SoftwareControlled
PulseOnStartofFrame
PulseOnStartofLine
PulseOnStartofExposure
PulseOnEndofExposure
PulseOnStartofReadout
PulseOnEndofReadout
PulseOnValidLineTrigger
PulseOnInvalidLineTrigger
PulseOnStartofAcquisition
PulseOnEndofAcquisition
PulseOnTimer1End
PulseOnTimer2End
PulseOnCounter1End
PulseOnCounter2End
PulseOnInput1
PulseOnInput2
PulseOnInput3
PulseOnInput4
PulseOnRotaryEncoder1
PulseOnSoftwareCmd
FrameTriggerActive
FrameActive
ExposureActive
ReadoutActive
SmartStrobeActive
Controls whether to invert the polarity of the selected
input or output line signal.
Specifies the minimum delay before an input line voltage
transition is recognizing as a signal transition.
Controls if the electrical termination of the select ed line is
enabled or disabled.
Disables electrical line termination for the selected line.
Enables electrical line termination for the selected line.
Selects which internal signal or event driven pulse or
software control state to output on the selected line. Note,
the LineMode feature must be set to Output. The List of
supported output line sources is product-specific. The
Event Control section
provides details and timing diagrams
for the supported trigger modes.
Off
Line output is Open
The OutputLineValue feature changes the state of the
output
Generate a pulse on the start of the Frame Active event
Generate a pulse on the start of the Line Active
Generate a pulse on the ExposureStart event. This option
is typically used to trigger a strobe light.
Generate a pulse on the ExposureEnd event. This option is
typically used to trigger a strobe light.
Generate a pulse on the ReadoutStart event.
Generate a pulse on the ReadoutEnd event.
Generate a pulse on the LineTrigger event.
Generate a pulse on the Invalid LineTrigger event.
Generate a pulse when the AcquisiontStart event occurs
Generate a pulse when the AcquisiontStop event occurs
Generate a pulse on the TimerEnd 1 event.
Generate a pulse on the TimerEnd 2 event.
Generate a pulse on the CounterEnd 1 event.
Generate a pulse on the CounterEnd 2 event.
Generate a pulse on the Input signal 1 event
Generate a pulse on the Input signal 2 event
Generate a pulse on the Input signal 3 event
Generate a pulse on the Input signal 4 event
Generate a pulse on the Rotary Encoder 1 event
Generate a pulse on the Input of a Software Command
Generate a signal that is active when the frame trigger is
active
Generate a signal that is active when the Frame is active
Generate a signal that is active when the Exposure is
active
Generate a signal that is active when the line valid is
active
Generate a signal that is active when the Readout or the
ExposureDelay are active. The smart strobe only works
when triggerLineCount is greater than 1