Teledyne Linea Color GigE LA-GC-02k05B User Manual page 46

Table of Contents

Advertisement

Rotary Encoder Input B
Source
GND
Line 2
Line 4
Rotary Encoder Source
Activation
Rising Edge
Any Edge
Rotary Encoder Rescaler
Order
Multiplier Divider
Divider Multiplier
Rotary Encoder Multiplier
Rotary Encoder Divider
Line Selector
Line 1
Line 2
Line 3
Line 4
Line 5
Line 6
Line Format
SingleEnded
Open Collector
RS422
Line Mode
Input
Output
Input Line Detection Level
Threshold for 3.3V LVTTL
Threshold for 5V TTL
Threshold for 12V
Threshold for 24V
Line Status
44 • Operational Reference
rotaryEncoderInputBSource
GND
Line2
Line4
rotaryEncoderSrcActivation
RisingEdge
AnyEdge
rotaryEncoderRescalerOrder
multiplierDivider
dividerMultiplier
rotaryEncoderMultiplier
rotaryEncoderDivider
LineSelector
Line1
Line2
Line3
Line4
Line5
Line6
LineFormat
SingleEnded
OpenCollector
RS422
LineMode
Input
Output
lineDetectionLevel
Threshold_for_3V3
Threshold_for_5V
Threshold_for_12V
Threshold_for_24V
LineStatus
False / True
Selects which input line to assign to the rotary encoder
input B (also known as shaft encoder). Note that the Line
Mode feature must be set to Input. The list of supported
input line sources is device-specific.
Rotary Encoder Input B is not used
Line2 is assigned to the Rotary Encoder Input B
Line4 is assigned to the Rotary Encoder Input B
Specifies the signal edge(s) use to increment the rotary
encoder.
The rotary encoder uses the rising edge of the source
signal.
The rotary encoder uses either the rising edge or falling
edge of the source signal.
Specifies the order that the multiplier and divider are
applied.
The signal is multiplied before been divided.
The signal is divided before been multiplied.
Specifies a multiplication factor for the rotary encoder
output pulse generator.
Specifies a division factor for the rotary encoder output
pulse generator.
Selects the physical line (or pin) of the external device
connector to configure.
Index of the physical line and associated I/O control block
to use.
Specify the current electrical format of the selected
physical input or output. Applies to all physical lines. (RO)
The line is single ended input for 3.3V/5V/12V/24V or
output for 3.3V LVTTL
The line is output as open collector.
The line accepts or sends RS422 level signals.
Reports if the physical Line is an Input or Output signal.
(RO)
See Input Signals Electrical Specifications.
See Output Signals Electrical Specifications.
The line is an input line.
The line is an output line.
Specifies the voltage threshold required to recognize a
signal transition on an input line.
A signal below 1.5V will be detected as a Logical LOW and
a signal greater than 1.5V will be detected as a Logical
HIGH on the selected input line.
A signal below 2.5V will be detected as a Logical LOW and
a signal greater than 2.5V will be detected as a Logical
HIGH on the selected input line.
A signal below 5.0V will be detected as a Logical LOW and
a signal greater than 5.0V will be detected as a Logical
HIGH on the selected input line.
A signal below 5.0V will be detected as a Logical LOW and
a signal greater than 5.0V will be detected as a Logical
HIGH on the selected input line.
Returns the current status of the selected input or output
line. (RO)
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Guru
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Beginner
1.00
Expert
1.00
Expert
1.00
Expert
DFNC
1.00
Expert
Linea GigE Series Camera

Advertisement

Table of Contents
loading

This manual is also suitable for:

Linea color gige la-gc-04k05b