Output Line Details
The general purpose output line signals either dedicated or shared with inputs. See HD15 type
Connector Details for connector pinout and electrical information.
•
Feature set: LineInverter (RW), outputLineSource (RW), outputLinePulseDelay (RW),
outputLinePulseDuration (RW), outputLineValue (RW), outputLineSoftwareCmd (RW),
LineSelector (RW), LineFormat (RW), LineMode (RW), LineStatus (RO). See Output Signals
Electrical Specifications for more information.
•
External outputs: Can be used as a strobe signals to control lighting or to generate
programmable pulses when specific events are generated by the camera.
•
Output on Events: Each output can be set independently to one of the available event modes
defined by the 'outputLineSource' feature. The output delay can be set from 0 to 16 seconds, in
increments of 1 µs. The pulse duration can be set from 0 to 16 seconds, in increments of 1 µs.
Example of Free Run Line Mode with Frame Trigger
An example setup of free run line acquisition with Frame Trigger with a configurable internal timer
is used as follows:
•
Set "AcquisitionLineRate" as 20000Hz
•
Set image Height as 100
•
Select "TriggerSelector" as "SingleFrameTrigger(Start)"
•
Set "TriggerMode" as "On"
•
Select TriggerSource as "Timer1EndEvent"
•
Setup Timer1:
•
Set its TimerStartSource as "Timer1End"
•
TimerDuration as 5000
•
TimerMode set as "Active"
Then click on the CamExpert "Grab" button.
Example of Line Trigger Mode
An example setup of a Line Trigger acquisition using internal timer with a configurable internal
timer is as follows:
•
Set image "Height" as 100
•
Select "TriggerSelector" as "SingleLineTrigger(Start)"
•
Set "TriggerMode" as "On"
•
Select TriggerSource as "Timer1EndEvent"
•
Setup Timer1:
•
Set its TimerStartSource as "Timer1End"
•
TimerDuration as 100
•
TimerMode set as "Active"
Then click on the CamExpert "Grab" button.
50 • Operational Reference