Example of Line Trigger plus Frame Trigger Combined
An example setup the Line Trigger mode combined with Frame Trigger using the configurable
internal timers is as follows:
Set image "Height" as 80
Select "TriggerSelector" as "SingleLineTrigger(Start)"
Set "TriggerMode" as "On"
Select TriggerSource as "Timer1EndEvent"
Select "TriggerSelector" as "SingleFrameTrigger(Start)"
Set "TriggerMode" as "On"
Select TriggerSource as "Timer2EndEvent"
Set Timer1 "TimeDuration" as 100, and "TimerMode" as "Active"
Set Timer2 "TimeDuration" as 10000, and "TimerMode" as "Active"
Then click on the CamExpert "Grab" button.
Linea GigE Series Camera
Operational Reference • 51