Teledyne Linea Color GigE LA-GC-02k05B User Manual page 56

Table of Contents

Advertisement

Counter Incremental
Line Activation
Rising Edge
Falling Edge
Any Edge
Counter Reset Source
Reset Cmd
Acquisition Start
Acquisition End
Exposure Start
Exposure End
Readout Start
Readout End
Frame Trigger
Line 1
Line 2
Line 3
Line 4
Timer 1 End
Timer 2 End
Counter 1 End
Counter 2 End
Counter Reset Input
Line Activation
Rising Edge
Falling Edge
Any Edge
Counter Duration
Counter Value
Counter Value At Reset
Counter Reset
Timer Selector
Timer 1
Timer 2
Timer Mode
Off
Active
54 • Operational Reference
counterIncrementalLineActivation
RisingEdge
FallingEdge
AnyEdge
counterResetSource
AcquisitionStart
AcquisitionEnd
ExposureStart
ExposureEnd
ReadoutStart
ReadoutEnd
FrameStart
Timer1End
Timer2End
Counter1End
Counter2End
counterResetLineActivation
RisingEdge
FallingEdge
AnyEdge
counterDuration
counterValue
counterValueAtReset
counterReset
timerSelector
Timer1
Timer2
timerMode
Active
Selects the counter signal activation mode for line inputs.
The counter increments on the specified signal edge or
level.
Increment the counter on the rising edge of the selected I/O
Line.
Increment the counter on the falling edge of the selected
I/O Line.
Increment the counter on the falling or rising edge of the
selected I/O Line.
Selects the signal source to reset the counter then waits for
the next countStartSource signal or event.
Off
Reset on reception of the Reset command.
Reset on reception of the Acquisition Start.
Reset on reception of the Acquisition End.
Reset on reception of the Exposure Start event.
Reset on reception of the Exposure End event.
Reset the counter on the reception of the Readout Start
event.
Reset the counter on the reception of the Readout End
event.
Reset on reception of the Frame Trigger.
Reset counter on the specified transition on line 1.
Line1
See Input Signals Electrical Specifications.
Line2
Reset counter on the specified transition on line 2.
Line3
Reset counter on the specified transition on line 3.
Line4
Reset counter on the specified transition on line 4.
Reset on reception of the Timer 1 End.
Reset on reception of the Timer 2 End.
Reset on the reception of the Counter 1 end.
Reset on the reception of the Counter 2 end.
Specify the edge transition on the selected line that will
reset the selected counter.
Reset counter on rising edge of the selected signal.
Reset counter on falling edge of the selected signal.
Reset counter on the falling or rising edge of the selected
signal
Sets the duration (or number of events) before the
CounterEnd event is generated.
Read the current value of the selected counter. (RO)
Reads the value of the selected counter when it w as reset
by a trigger or by an explicit Counter Reset command. (RO)
Resets the selected counter to zero. The counter starts
immediately after the reset. To temporarily disable the
counter, set the Counter Event Source feature to Off. (WO)
Selects which timer to configure.
Configure Timer 1
Configure Timer 2
Select the timer mode. The selected Timer is Active or
Disabled. When Disabled, the Timer can be configured.
Off
The selected Timer is Disabled.
The selected Timer is Enabled.
1.00
Expert
DFNC
1.10
Expert
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC
Linea GigE Series Camera

Advertisement

Table of Contents
loading

This manual is also suitable for:

Linea color gige la-gc-04k05b

Table of Contents