Error 32: Error I>0
 Current recording is faulty.
Request service.
Error 33: Error UIST
 Voltage recording is faulty.
Eliminate the short circuit in the welding circuit.
Remove the external sensor voltage.
Request service.
Error 34: Electronics error
 A/D channel error
Switch the machine off and on.
Request service.
Error 35: Electronics error
 Slope error
Switch the machine off and on.
Request service.
Error 36:
errors
conditions violated.
Switch the machine off and on.
Request service.
Error 37: Electronics error
 The power source is overheating.
Allow the switched-on machine to cool.
 Fan is blocked, dirty or defective.
Check fan and clean or replace.
 Air inlet or outlet is blocked.
Check the air inlet and outlet.
Error 38: Error IIST
 Short circuit in the welding circuit before welding.
Eliminate the short circuit in the welding circuit.
Request service.
Error 39: Electronics error
 Overvoltage on secondary
Switch the machine off and on.
Request service.
Error 40: Electronics error
 Error I>0
Request service.
Error 47: Error in the data interface with radio transmission
Category B
 Connection error between welding machine and peripheral unit.
Note the documentation for the data interface with radio transmission.