Manual Ignition Setting - EWM T5.01-DC Comfort 3.0 Operating Instructions Manual

Table of Contents

Advertisement

5.1.4

Manual ignition setting

When the special ignition is selected, the dependency of the minimum current limits on the electrode dia-
meter is disabled. The ignition energy can now be set independently with the parameters ignition current
and ignition time
current differs in the setting variants
In the variant
In the variant
The parameters for manual setting of the ignition energy are selected and enabled with "left stop" when
setting the electrode diameter (minimum value >
099-00T501-EW501
1.8.2022
. The ignition time is set absolutely in milliseconds. The setting of the ignition
and
, the ignition current is set absolutely in ampere [A].
, the ignition current is set as a percentage of the set main current.
Functional characteristics
.
>
).
Figure 5-3
TIG welding