Responsiveness; Expert Menu (Tig) - EWM T5.01-DC Comfort 3.0 Operating Instructions Manual

Table of Contents

Advertisement

5.1.12.2 Responsiveness

This function controls the responsiveness of the welding current during the main current phase. The user
can choose between linear and logarithmic responsiveness. The logarithmic setting is particularly suitable
for welding with low current, e.g., for thin panels as the logarithmic responsiveness enables better control
of the welding current.
The responsiveness function can be switched in the machine configuration menu between the parame-
ters for linear and logarithmic responsiveness (factory set) > see 5.9 chapter.

5.1.13 Expert menu (TIG)

The Expert menu has adjustable parameters stored that don't require regular setting. The number of pa-
rameters shown may be limited, e.g. if a function is deactivated.
Display
099-00T501-EW501
1.8.2022
2s
Setting/selection
Slope time (main current to secondary current)
Functional characteristics
Figure 5-27
Figure 5-28
TIG welding
2s