Functional characteristics
Machine configuration menu
Display
for AC welding machines only.
1
For machines with filler wire (AW) only.
2
for components for automated welding (RC) only.
3
58
Setting/selection
Error output to interface for automated welding, contact SYN_A
------- AC synchronisation or hot wire (ex works)
------- Error signal, negative logic
------- Error signal, positive logic
------- AVC (Arc voltage control) connection
Fast take-over of control voltage (automation)
------- Function enabled
------- Function disabled (ex works)
Welding procedure DC+ (TIG)
Protection against an accidental selection of polarity DC+ and the associated destruction
of the tungsten electrode (factory setting).
------- Polarity switching to DC+ is possible.
------- Polarity switching is disabled (factory setting).
Gas monitoring
Depending on where the gas sensor is situated, the use of a pilot static tube and the
welding process monitoring phase.
------- Function disabled (ex works).
------- Monitoring during the welding process. Gas sensor between gas valve and
welding torch (with pilot static tube).
------- Monitoring prior to the welding process. Gas sensor between gas valve and
welding torch (without pilot static tube).
------- Permanent monitoring Gas sensor between gas cylinder and gas valve (with
pilot static tube).
Arc detection for welding helmets (TIG)
Modulated waviness for better arc detection
------- Function disabled
------- Medium intensity
------- High intensity
3