1. Install bolt in door.
NOTE: The bolt must be in a retracted (unlocked) position
when installing the lockset.
Attach with (2) M4 x 25.4mm [8-32 x 1"] screws supplied.
2. Install strike on the door frame, making sure to allow
for the bolt to be centered in the strike.
3. Install outside escutcheon.
As you position the outside escutcheon, route the
cable through 2-1/8" diameter hole (Figure 3A).
NOTE: Cable goes under bolt (see Fig. 3B).
4. Holding the outside escutcheon flush to the door,
position the inside mounting plate by first routing
the cable and connector through the mounting
plate's 1/2" hole (Fig. 4A) and then inserting the
mounting plate "tongue" into the bottom slot of the
outside escutcheon (Fig. 4B).
An ASSA ABLOY Group brand
Figure 4A

INSTALL LOCK

"Tongue"
1
(2) M4 x 25.4mm
[8-32 x 1"]
Flat Head
Combination Screws
2
(2) M4 x 25.4mm
[8-32 x 1"]
Flat Head
Combination Screws
Figure 3A
Figure 3B
Figure 4B
P/N AYRD210-INST-FUL Rev B