Command Class Battery, Version 1*

* This command class requires security.
Per the Z-Wave Plus ™ Specification, the lock will send a Battery Report with a
value of 0xFF to the Lifeline node when a critical battery level is reached (starting
at about 4.2V for Product Type ID 0x8101 & 0x8112). In addition, the Yale Locks
provide 2 earlier low battery alarms through the notification command class (see
Table 7 - Notification Table).
Low battery alarms will be generated if the lock is in a low battery state during one
of the following events: any motor activation (keypad lock/unlock, RF lock/unlock,
etc.), controller sends Get Battery command, or the unsolicited battery report was
triggered. Yale locks will generate an unsolicited Battery Report at lock boot-up and
every 8 hours if a node is listed in the Lifeline Group.

Command Class Door Lock, Version 4*

* This command class requires security.
Yale Z-Wave Plus ™ locks support three door lock modes: Door Secured (0xFF),
Door Unsecured (0x00), and Door Unsecured with timeout (0x01). When Auto
Relock is enabled, the lock will automatically relock after all unlock events. Yale Z-
Wave Plus ™ locks do not support any of the "Door Unsecured for outside Door
Handles" (0x20, 0x21) or "Door Unsecured for inside Door Handles" (0x10, 0x11)
modes.

Command Class Door Lock Logging, Version 1*

* This command class requires security.
This command class has been implemented per the Z-Wave™ Specification.

Command Class Schedule Entry Lock, Version 3*

* This command class requires security.
Yale locks support Year Day Schedule types and Daily Repeating Schedule types.
Yale locks allow the controller to apply multiple schedules to a single user. Each
user has 1 Year Day Schedule slot (Slot ID 1) and 7 Daily Repeating slots (Slot IDs
1 – 7). If user scheduling is used in the lock, then the controller MUST set the
lock's time using the Time Parameters command class.