For Firmware Target 0, the Firmware 0 Version (0x02) and Sub version (0x22)
translate to module firmware decimal value of "2.34".
For Firmware Target 1 (the data under vg1), Firmware Version (0x2C) and Sub
version (0x00) translate to lock firmware decimal value of "4.3.00".

Command Class Battery, Version 1*

* This command class requires security.
Per the Z-Wave Plus ™ Specification, the lock will send a Battery Report with a
value of 0xFF to the Lifeline node when a critical battery level is reached (starting
at about 4.2V for Product Type ID 0x8100 & 0x8111). In addition, the Yale Locks
provide 2 earlier low battery alarms through the notification command class (see
Table 7 - Notification Table).
Low battery alarms will be generated if the lock is in a low battery state during one
of the following events: any motor activation (keypad lock/unlock, RF lock/unlock,
etc.), controller sends Get Battery command, or the unsolicited battery report was
triggered. Yale locks will generate an unsolicited Battery Report at lock boot-up and
every 8 hours if a node is listed in the Lifeline Group.

Command Class Door Lock, Version 4*

* This command class requires security.
Yale Z-Wave Plus ™ locks support three door lock modes: Door Secured (0xFF),
Door Unsecured (0x00), and Door Unsecured with timeout (0x01). When Auto
Relock is enabled, the lock will automatically relock after all unlock events. Yale Z-
Wave Plus ™ locks do not support any of the "Door Unsecured for outside Door
Handles" (0x20, 0x21) or "Door Unsecured for inside Door Handles" (0x10, 0x11)
modes.