Ce document est disponible sur notre site Web dans le français imprimé. Allez à www.yalecommercial.com. Cliquez sur le " ; Information sur le produit et Documentation" et puis " Installation Instructions". P/N 80-9150-0065-010 Rev B An ASSA ABLOY Group brand...
"Easy" mode. The desired operating mode should be de- termined before the completion of lock installation, but can be changed at a later time if required. P/N 80-9150-0065-010 Rev B An ASSA ABLOY Group brand...
1" (26mm) boring bit Lever removal tool (supplied) 5/16" (8mm) drill bit 3/8" or 1/2" drill 7/64" (2.5mm) drill bit 3/32" Allen wrench (supplied) Chisel & hammer P/N 80-9150-0065-010 Rev B An ASSA ABLOY Group brand...
C. Align the holes of the strike with the vertical line. Trace Optional Strike Box #202 the outline of the strike and mortise with a 1/16" (1.6mm) depth. Attach the strike with two screws (provided). Attaching Screws 81-2012-0620 #12-12-24x1" P/N 80-9150-0065-010 Rev B An ASSA ABLOY Group brand...
Hinges on right. Opens outward. Opens inward. Opens inward. Opens outward. For handed locks, For handed locks, for handed locks, For handed locks, specify LHR. specify LH. specify RH. specify RHR. P/N 80-9150-0065-010 Rev B An ASSA ABLOY Group brand...
Page 6
CAUTION: The cylinders furnished with inTouch™ lock for use in 1-3/8" doors have a tailpiece that is 1/4" shorter than the standard cylinders that are furnished for 1-3/4" doors. Trying to install a standard cylinder in 1-3/8" will DAMAGE the lock body. P/N 80-9150-0065-010 Rev B An ASSA ABLOY Group brand...
2-1/8" diameter hole. as illustrated. b. Guide touchscreen cable through 3/4" 8. Select EASY or ADVANCED Mode using the diameter upper hole. switch on the back of the PC board. P/N 80-9150-0065-010 Rev B An ASSA ABLOY Group brand...
Remove latchbolt and insert lockset. Look though latchbolt hole and verify retractor mouth centered in hole. If not, adjust outside rose plate. c. If necessary, rebore holes to line up retractor and tail. P/N 80-9150-0065-010 Rev B An ASSA ABLOY Group brand...
Battery Cover " I " Button Touchscreen 4 AA Battery Alkaline Passage Mode Batteries Lockout Mode Cylinder Status LED Speaker 9 Volt Emergency Power Supply Terminal 9 Volt Batteries Purchased Separately P/N 80-9150-0065-010 Rev B An ASSA ABLOY Group brand...
Page 10
Supervisor code. If Group Lockout is enabled through the Master code, specific Supervi- sors and their entire group of Users will be locked out. If Group Lockout is enabled through the Supervisor code, only Users corresponding to that Supervisor are locked out. P/N 80-9150-0065-010 Rev B An ASSA ABLOY Group brand...
Page 11
Wrong Code Entry Limit: After a default of five (5) unsuccessful attempts at entering a valid PIN code the unit will shut down and not allow operation. Wrong code entry limit is adjustable from one (1) to ten (10) times in Advanced mode only through feature settings. P/N 80-9150-0065-010 Rev B An ASSA ABLOY Group brand...
Set/Change User PIN (1 - 8) Operation of Lock Turn lever to Touch lock with palm Palm or touch the Enter PIN code. open door. of hand or fingers to confirm the selection. to activate. P/N 80-9150-0065-010 Rev B An ASSA ABLOY Group brand...
Page 13
20 seconds. If time 4. Press the key to complete expires, no codes are registered and the process the process and conclude the French must be re-started. programming session. P/N 80-9150-0065-010 Rev B An ASSA ABLOY Group brand...
Set Language Setting Mode Operation of Lock Turn lever to Touch lock with palm Palm or touch the Enter PIN code. open door. of hand or fingers to confirm the selection. to activate. P/N 80-9150-0065-010 Rev B An ASSA ABLOY Group brand...
Page 15
Group Lockout Mode 00-19 Disable 00-19 Enable Passage Mode Disable Enable Silent Mode Disable Re-lock Time Lock Setting Mode Wrong Code Entry Limit Shut Down Time English Language Setting Mode Spanish French P/N 80-9150-0065-010 Rev B An ASSA ABLOY Group brand...
Page 16
5. Enter the User number to be registered (01-49) followed by the key. 6. Enter a 4-12 digit PIN code for the User number followed by the key. 7. Press the key to complete the process and conclude the programming session. P/N 80-9150-0065-010 Rev B An ASSA ABLOY Group brand...
While connecting the 9V battery, the lock can be operated as normal, thus granting access so the 4 AA alkaline batteries can be replaced. Discharged batteries should be replaced right away. P/N 80-9150-0065-010 Rev B An ASSA ABLOY Group brand...
AA Alkaline batteries. Upon entering a PIN code and press- • The digits entered were incorrect or incomplete. Re-enter the code. ing the star (*) key, the unit responds “Wrong digit numbers.” P/N 80-9150-0065-010 Rev B An ASSA ABLOY Group brand...
User 16 User 42 User 17 User 43 User 18 User 44 User 19 User 45 User 20 User 46 User 21 User 47 User 22 User 48 User 23 User 49 P/N 80-9150-0065-010 Rev B An ASSA ABLOY Group brand...
Page 20
100 Yale Avenue, Lenoir City, TN 37771 • Product Support Tel 800.438.1951 • Fax 800.338.0965 • www.yalecommercial.com Yale® and is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. inTouch™ is a trademark of Yale Security Inc., an ASSA ABLOY Group company.
Need help?
Do you have a question about the Yale inTouch and is the answer not in the manual?
Questions and answers