  • Page 1 Yale Locks Z-Wave Plus ™ v2 System Integrators Guide Yale Assure Electronic Connected Biometric Deadbolts Document Revision: 1.0 June 2023...
  • Page 2: Table Of Contents

    Contents Revision History ..................4 Yale Z-Wave Plus ™ Product Info ..............5 Network Operations ..................5 Enroll/Add device to network (SmartStart) ........... 5 Enroll/Add device to network (Classic Inclusion Mode) for Assure Lock [YRC/D216/226/256/622/642/652, NF-YRC/D612/622] ..Error! Bookmark not defined.
  • Page 3 Command Class Configuration, Version 4* ..........25 Command Class Application Status, Version 1 ..........28 Command Class Transport Service, Version 2 ..........28 Command Class Supervision, Version 1 ............28 Command Class Indicator, Version 3* ............28 Command Class Basic, Version 2* ............. 29 * This command class requires security.
  • Page 4: Revision History

    Revision History Rev. Details Initial Release...
  • Page 5: Yale Z-Wave Plus ™ Product Info

    Yale Z-Wave Plus ™ Product Info Manufacturer ID: ASSA ABLOY (0x0129) Z-Wave ™ Device Type: Door Lock Keypad Z-Wave Role Type: Listening Sleeping Slave (LSS) ™ Network Operations Enroll/Add device to network (SmartStart) SmartStart enabled products can be added into a Z-Wave network by scanning the ™...
  • Page 6: Un-Enroll/Remove Device From Network (Exclusion Mode)

    Enroll/Add device to network (Classic Inclusion Mode) for Assure 2 Lock Un-enroll/Remove device from network (Exclusion Mode) • Enter the 4–8-digit Master PIN code followed by the key. • Press the key followed by the key. • Press the key followed by the key.
  • Page 7: Supported Command Classes

    Supported Command Classes The Yale Assure Z-Wave Plus ™ deadbolts follow the Z-Wave ™ Command Class Specifications for all command classes that are implemented. Please refer to these specifications for specifics on how each command class works. The supported command classes are listed below, and certain sections contain details about operations that may be specific to the Yale lock.
  • Page 8: Command Class Manufacturer Specific, Version 2

    * This command class requires security. The Manufacturer Specific command class reports the following information: • Manufacturer ID: 0x0129 o This is the manufacturer ID assigned to ASSA ABLOY. • Product ID: o The Product ID can be used to differentiate between hardware platforms, as well as between ZW2 and ZW3.
  • Page 9: Command Class Device Reset Locally, Version 1

    Command Class Device Reset Locally, Version 1* * This command class requires security. The Yale door locks covered in this guide can be reset to their factory default settings by manually resetting the lock or by BLE command via app for BLE locks (by following the procedure outlined in the specific lock’s manual).
  • Page 10: Command Class Version, Version 3

    Command Class Version, Version 3* * This command class requires security. The Yale Real Living locks are a multi-processor system with 1 additional firmware target. All processors can be updated through the Firmware Update Meta Data command class. The firmware targets are numbered as follows: •...
  • Page 11: Command Class Battery, Version 1

    Command Class Battery, Version 1* * This command class requires security. Per the Z-Wave Plus ™ Specification, the lock will send a Battery Report with a value of 0xFF to the Lifeline node when a critical battery level is reached (starting at about 4.2V for Product Type ID 0x8107).
  • Page 12: Command Class User Code, Version 2

    Command Class User Code, Version 2* * This command class requires security. Versions 1 and 2 of this command class can address user code slots 1 through 250 via the User Code Set/Get/Report commands. Version 2 of this command class also includes extended versions of each of these commands, used to address the extended range of users.
  • Page 13 (now called “Messaging”) user ID status is assigned a value of 0x03. This value of 0x03 should be used with the Extended User Code Set command. • A non-access user can be identical to a “normal” PIN code, aside from the fact that it does not grant access.
  • Page 14 User ID User Code CC v2: Extended User Code CC v2: Extended User Status User Code Set Code Report Value Description Value Value Available 0x00 0x00 Enabled / 0x01 0x01 Grant Access Disabled 0x02 0x02 Messaging: The user code is accepted, but the lock does not grant access to the...
  • Page 15: Command Class Time Parameters, Version 1

    Command Class Time Parameters, Version 1* * This command class requires security. The controller must set the Time Parameters in the lock anytime the lock loses power. After 10 seconds from lock enrollment, if there are no messages from the controller the lock will initially request the Time (by sending Time Get and Time Parameter Get commands).
  • Page 16: Command Class Firmware Update Meta Data, Version 5

    Firmware Target 0 is used to determine the correct Z-Wave ™ processor image to download. ID 1 is always 0xA5, to signal this is an ASSA ABLOY Z-Wave ™ image, and ID 2 is specific to the region, with the lower nibble being 0x0 and the upper nibble being the value in Table 4 - Region-Specific Values for Firmware ID 0.
  • Page 17: Command Class Association, Version 2

    The following is the time it takes for each product to complete OTA image apply phase: • For Z-Wave ™ Radio Chip, ~10 seconds • For YRD410-F-ZW3, YRD420-F-ZW3, YRD430-F-ZW3 & YRD450-F-ZW3 (2nd Generation Assure Biometric Deadbolt), ~23 minutes (full image) ~5 minutes (patch/differential image) Command Class Association, Version 2* * This command class requires security.
  • Page 18: Command Class Association Group Info, Version 3

    Command Class Association Group Info, Version 3* * Command Class Requires Security Yale locks support the Lifeline Association Group. Table 5 - Association Table Group ID Maximum Nodes Description Commands • Command Class Battery Battery Report • Command Class Configuration Configuration Report •...
  • Page 19 The following are the actions to trigger the reports: Table 6 – Lifeline Report Trigger Table Report Command RF Trigger Manual Trigger Battery Report Any RF Lock Operation when lock is Any manual/keypad Lock Operation under the battery thresholds when lock is under the battery thresholds or Power Cycle Lock Configuration Report Configuration Set...
  • Page 20: Command Class Notification, Version 8

    Command Class Notification, Version 8* * This command class requires security. Table 7 - Notification Table Alarm Notification Alarm Reports Alarm Level Description Event type Type 0x01 Deadbolt jammed while locking 0x06 0x0B Deadbolt Jammed 0x09 0x02 Deadbolt jammed while unlocking 0x06 0x0B 0x (01 –...
  • Page 21 0x01 By key cylinder or inside thumb turn 0x06 0x02 Manual Unlock 0x16 0x02 By inside button 0x06 0x02 RF Operate Lock 0x18 0x01 by RF module 0x06 0x03 RF Operate Unlock 0x19 0x01 by RF module 0x06 0X04 Auto Lock Operate 0x1B 0x01 Auto re-lock cycle complete, locked.
  • Page 22 Daily Repeating 0x (01-max Schedule(s) has been set/erased for 0x60 0x06 0xFE Schedule Set/Erased users) specified user ID 0x (01-max Daily Repeating Schedule(s) were Daily Repeating 0x61 users) enabled/disabled for User ID specified 0x06 0xFE Schedule in Alarm Level. If Alarm Level = 0xFF Enabled/Disabled then all users were affected.
  • Page 23 After a low battery alert was Battery is fully 0x80 0x05 observed, the lock was powered down 0x08 0x0D charged and powered back up with full battery. 0x00 Right-handed install 0x06 0xFE Handing Cycle 0x81 completed 0x01 Left-handed install 0x06 0xFE Power to the lock was restored and Door Lock needs Time...
  • Page 24 Homekit BLE Lock ⁴ 0xE4 0x00 Integrated Homekit BLE Lock 0x06 0x03 Homekit BLE Unlock ⁴ 0xE5 0x00 Integrated Homekit BLE Unlock 0x06 0X04 ¹ Deleting all user codes will also delete any associated schedules (year day and daily repeating scheduled pin codes) assigned to user codes.
  • Page 25 Command Class Configuration, Version 4* * This command class requires security. Table 8 - Configurable Parameters Length of Configuration Properties Info Info String (Max length Param. allowed is Num. Name Length Default 0x01 (High 0x03 0x01 (High Set Volume Level to high Volume 1 byte Volume)
  • Page 26 Adjust the time your lock is shutdown after 0x0A (10 0x84 (132 0x3C (60 reaching its wrong code Shut down time 1 byte seconds) seconds) seconds) entry limit. Set the Operating Mode to 0x00 0x03 0x00 normal mode, keypad Operating mode² 1 byte (Normal (Passage...
  • Page 27 Timeout value used to Expiring Pin Code 0x00 0xFF (127 0x00 1 byte determine time after first Enabled Time (Disable) Hours) (Disable) entry is triggered. ¹ Even though the lock accepts value 0x01 for Auto Relock Time, we limit the lock’s minimum to value of 0x03. Therefore, if user tries to set Auto Relock Time to values 0x01 or 0x02, it will always report back value of 0x03.
  • Page 28 Command Class Application Status, Version 1 This command class has been implemented per the Z-Wave ™ Specification. Command Class Transport Service, Version 2 This command class has been implemented per the Z-Wave ™ Specification. Command Class Supervision, Version 1 This command class has been implemented per the Z-Wave ™...
  • Page 29 Command Class Basic, Version 2* * This command class requires security. This command class is mapped to Door Lock CC: Table 11 – Basic Mapping Overview Basic Command Door Lock Mapped Command Basic Set (Value) Door Lock Operation Set (Door Lock Mode) Basic Report (Current Value = 0x00) Door Lock Operation Report (Door Lock...