  • Page 1 Yale Locks Z-Wave Plus ™ v2 System Integrators Guide Yale Assure Electronic Deadbolts YRD216-ZW3, YRD226-ZW3, YRD256-ZW3, YRC216-ZW3, YRC226-ZW3, YRC256-ZW3, YRD652-ZW3, NF-YRD622-ZW3, NF-YRD612-ZW3, YRC652-ZW3, NF-YRC622-ZW3, NF-YRC612-ZW3, YRD622-ZW3, YRD642-ZW3, YRC622-ZW3, YRC642-ZW3, YRD410-ZW3, YRD420-ZW3, YRD430-ZW3, YRD450-ZW3, YRD622-NN-ZW3, YRD642-NN-ZW3, YRC622-NN-ZW3, YRC642-NN-ZW3 Document Revision: 2.3 May 2023...
  • Page 2: Table Of Contents

    Contents Revision History ..................4 Yale Z-Wave Plus ™ Product Info ..............6 Network Operations ..................6 Enroll/Add device to network (SmartStart) ........... 6 Enroll/Add device to network (Classic Inclusion Mode) for Assure Lock [YRC/D216/226/256/622/642/652, NF-YRC/D612/622] ........7 Enroll/Add device to network (Classic Inclusion Mode) for Assure 2 Lock [YRD410/420/430/450] ................
  • Page 3 Command Class Application Status, Version 1 ..........32 Command Class Transport Service, Version 2 ..........32 Command Class Supervision, Version 1 ............32 Command Class Indicator, Version 3* ............32 Command Class Basic, Version 2* ............. 33 * This command class requires security.
  • Page 4: Revision History

    Revision History Rev. Details Initial Release Made the following updates: • Added Command Class Clock section. • Added Clock Report to the Association Group Info commands list. • Marked Time as a secure command class. • Added the following note to Time, Time Parameters, and Clock command classes: “If the controller does not support either the Time CC, Time Parameters CC, or Clock CC, then scheduled users will not have access.”...
  • Page 5 • Re-added Scheduling Alarms • Fixed Door State Alarm value • Added -NN (No NFC) SKUs • Added Handing Alarm • Fixed Master Code Change Alarm • Fixed Wrong Entry Code Limit Alarm • Fixed Auto Relock Time default and minimum for 400 Series Locks •...
  • Page 6: Yale Z-Wave Plus ™ Product Info

    Yale Z-Wave Plus ™ Product Info Manufacturer ID: ASSA ABLOY (0x0129) Z-Wave ™ Device Type: Door Lock Keypad Z-Wave Role Type: Listening Sleeping Slave (LSS) ™ Network Operations Enroll/Add device to network (SmartStart) SmartStart enabled products can be added into a Z-Wave network by scanning the ™...
  • Page 7: Enroll/Add Device To Network (Classic Inclusion Mode) For Assure Lock [Yrc/D216/226/256/622/642/652, Nf-Yrc/D612/622]

    Enroll/Add device to network (Classic Inclusion Mode) for Assure Lock [YRC/D216/226/256/622/642/652, NF- YRC/D612/622] • Enter the 4–8-digit Master PIN code followed by the key. • Press the key followed by the key. • Press the key followed by the key. •...
  • Page 8: Factory Reset

    Factory Reset • Factory resetting the lock with the Z-Wave ™ module installed will clear the Z- Wave network settings, causing the device to be removed from the ™ network. • The following is the method of performing a factory reset: 1.
  • Page 9: Command Class Manufacturer Specific, Version 2

    * This command class requires security. The Manufacturer Specific command class reports the following information: • Manufacturer ID: 0x0129 o This is the manufacturer ID assigned to ASSA ABLOY. • Product ID: o The Product ID can be used to differentiate between hardware platforms, as well as between ZW2 and ZW3.
  • Page 10 0x45D1 for YRD410-ZW3 (2nd Generation Assure Keyed Push ▪ Button Deadbolt) 0x45D2 for YRD420-ZW3 (2nd Generation Assure Keyed Touch ▪ Screen Deadbolt) 0x45D3 for YRD430-ZW3 (2nd Generation Assure Keyless Push ▪ Button Deadbolt) 0x45D5 for YRD450-ZW3 (2nd Generation Assure Keyless Touch ▪...
  • Page 11: Command Class Security, Version 1

    Table 1 - First 2 Digits of Product ID Z-Wave™ Type Platform Hex Value [0x8004/0x8002]-ZW2 0 0x06 [0x8004/0x8002]-ZW3 0 0x46 [0x8109/0x810A]-ZW2 1 0x0D [0x8109/0x810A]-ZW3 1 0x4D 0 0x12 [0x8103]-ZW2 0 0x52 [0x8103]-ZW3 [0x8104]-ZW2 1 0x05 [0x8104]-ZW3 1 0x45 1 0x1D [0x8113]-ZW2 1 0x5D [0x8113]-ZW3...
  • Page 12: Command Class Power Level, Version 1

    Command Class Power Level, Version 1* * This command class requires security. This command class has been implemented per the Z-Wave Specification. ™ The Power Level command class was implemented to allow controllers to set the transmit power for the door lock. This could be useful in large networks with many nodes, so that the lock can find working routes back to the controller while transmitting at a lower power.
  • Page 13: Command Class Battery, Version 1

    The above Version Report will be defined as this in the Z-Wave sniffer tool, ™ Zniffer: For Firmware Target 0, the Firmware 0 Version (0x02) and Sub version (0x22) translate to module firmware decimal value of “2.34”. For Firmware Target 1 (the data under vg1), Firmware Version (0x2C) and Sub version (0x00) translate to lock firmware decimal value of “4.3.00”.
  • Page 14: Command Class Door Lock, Version 4

    Command Class Door Lock, Version 4* * This command class requires security. Yale Z-Wave Plus ™ locks support three door lock modes: Door Secured (0xFF), Door Unsecured (0x00), and Door Unsecured with timeout (0x01). When Auto Relock is enabled, the lock will automatically relock after all unlock events. Yale Z- Wave Plus ™...
  • Page 15 Table 2 – Expected Reports for Set/Get Commands Slots 256- Command Slots 1-250 Slot 251 Slots 252-254 Slot 255 User Code CC User Code User Code User Code v1/v2: User User Code Report Report Report Report Code Get User Code CC Master User Code User Code...
  • Page 16 Table 3 - User ID Status User Code CC v1 vs v2 User ID Status User Code CC v1 Set User Code CC v1 Report Value Description Value Value Available 0x00 0x00 Enabled / Grant Access 0x01 0x01 0x02 Disabled 0x03 0x03 Messaging:...
  • Page 17 User ID User Code CC v2: Extended User Code CC v2: Extended User Status User Code Set Code Report Value Description Value Value Available 0x00 0x00 Enabled / 0x01 0x01 Grant Access Disabled 0x02 0x02 Messaging: The user code is accepted, but the lock does not grant access to the...
  • Page 18: Command Class Time Parameters, Version 1

    Command Class Time Parameters, Version 1* * This command class requires security. The controller must set the Time Parameters in the lock anytime the lock loses power. After 10 seconds from lock enrollment, if there are no messages from the controller the lock will initially request the Time (by sending Time Get and Time Parameter Get commands).
  • Page 19: Command Class Firmware Update Meta Data, Version 5

    Firmware Target 0 is used to determine the correct Z-Wave ™ processor image to download. ID 1 is always 0xA5, to signal this is an ASSA ABLOY Z-Wave ™ image, and ID 2 is specific to the region, with the lower nibble being 0x0 and the upper nibble being the value in Table 4 - Region-Specific Values for Firmware ID 0.
  • Page 20: Command Class Association, Version 2

    After an OTA is performed (a Firmware Update Status Report should return with successful), there is an additional step internally where we write/apply the image to the lock/module. When the image is being applied to the lock, the lock is unresponsive until completion of the applied image.
  • Page 21: Command Class Association Group Info, Version 3

    Command Class Association Group Info, Version 3* * Command Class Requires Security Yale locks support the Lifeline Association Group. Table 5 - Association Table Group ID Maximum Nodes Description Commands • Command Class Battery Battery Report • Command Class Configuration Configuration Report •...
  • Page 22 The following are the actions to trigger the reports: Table 6 – Lifeline Report Trigger Table Report Command RF Trigger Manual Trigger Battery Report Any RF Lock Operation when lock is Any manual/keypad Lock Operation under the battery thresholds when lock is under the battery thresholds or Power Cycle Lock Configuration Report Configuration Set...
  • Page 23: Command Class Notification, Version 8

    Command Class Notification, Version 8* * This command class requires security. Table 7 - Notification Table Alarm Alarm Notification Alarm Reports Description Event type Level Type 0x01 Deadbolt jammed while locking 0x06 0x0B Deadbolt Jammed 0x09 0x02 Deadbolt jammed while unlocking 0x06 0x0B 0x (01 –...
  • Page 24 RF Operate Lock 0x18 0x01 by RF module 0x06 0x03 RF Operate Unlock 0x19 0x01 by RF module 0x06 0X04 Auto Lock Operate 0x1B 0x01 Auto re-lock cycle complete, locked. 0x06 0x09 Locked 0x (01- 0X0D User was deleted. Alarm level = user (single) slot number users)
  • Page 25 0x (01- Daily Repeating Schedule(s) were Daily Repeating 0x61 enabled/disabled for User ID specified in 0x06 0xFE Schedule users) Alarm Level. If Alarm Level = 0xFF then Enabled/Disabled all users were affected. 0x (01- Year Day Schedule Schedule(s) has been set/erased for 0x62 0x06 0xFE...
  • Page 26 After a low battery alert was observed, Battery is fully charged 0x80 0x05 the lock was powered down and 0x08 0x0D powered back up with full battery. 0x00 Right-handed install 0x06 0xFE Handing Cycle 0x81 completed 0x01 Left-handed install 0x06 0xFE Power to the lock was restored and the Door Lock needs Time...
  • Page 27 ³ The Yale lock also supports a 3 low battery alarm: too low to operate. This alarm is sent out as a Battery Report (with value = 0xFF) through the Battery Command Class. This is the last low battery alarm level before the product stops functioning. Starting at 3.8V (0x8002 & 0x8004);...
  • Page 28: Command Class Configuration, Version 4

    Command Class Configuration, Version 4* * This command class requires security. Table 8 - Configurable Parameters Length of Info Configuration Properties Info String (Max length Param. allowed Num. Name Length Default is 90) 0x02 (Low Volume) Set Volume Level to [0x8002, high (1), low (2), or 0x8109,...
  • Page 29 0x0A (10 seconds) [0x8002, 0x810A, 0x8004, 0x8109, 0x8103 & 0x8113] 0x01 (1 seconds) 0xB4 (180 0x1E (30 Adjust the time your Relock time 1 byte [0x8104] ¹ seconds) seconds) lock will auto relock. 0x05 [0x8002, 0x810A, 0x8004, 0x8109, 0x8103 & Adjust the limit for 0x8113] wrong code entries...
  • Page 30 Set the Operating Mode to normal mode(0), vacation mode(1), privacy 0x02 (Privacy mode(2). [0x8002, Mode) 0x8004, 0x8109 & [0x8002, 0x810A] 0x8004, Set the Operating 0x8109 & Mode to normal 0x810A] Operating mode 0x00 (Normal 0x00 (Normal 1 byte mode, keypad ³...
  • Page 31 Escape Return 0xFF (Enable) 0x00 Enable or Disable Mode ⁵ 1 byte 0x00 (Disable) ⁶ (Disable) Escape Return Mode Door Propped 1 byte 0x00 (Disable) 0xFE (2540 0x00 Adjust the time to Timer ⁷ ⁸ seconds) ⁸ (Disable) ⁸ receive an alert when the door is propped open.
  • Page 32 Command Class Application Status, Version 1 This command class has been implemented per the Z-Wave ™ Specification. Command Class Transport Service, Version 2 This command class has been implemented per the Z-Wave ™ Specification. Command Class Supervision, Version 1 This command class has been implemented per the Z-Wave ™...
  • Page 33 Command Class Basic, Version 2* * This command class requires security. This command class is mapped to Door Lock CC: Table 11 – Basic Mapping Overview Basic Command Door Lock Mapped Command Basic Set (Value) Door Lock Operation Set (Door Lock Mode) Basic Report (Current Value = 0x00) Door Lock Operation Report (Door Lock...