Notifications Table Alarm Alarm Reports Alarm Level Description type 0x00 Master code was changed at keypad Master Code changed. 0xFB Master code was changed over RF 0x70 0x(01-max User added User added. Alarm level = user slot number users) 0x(01-max User deleted 0x21 User was deleted.
Page 5
and plays the “Denied”. Trying to duplicate the master code will result in a 0x71 0x00 alarm report. Power to RFM was restored, sent by RF module. The RF Module Power 0x82 0x00 lock doesn’t send any alarm to the RF module when Cycled power is cycled.
Configurable Parameters Configuration Parameter Size Description Parameters Number Level control, 1 = High Volume, 3 = Silent. Default is 1 Silent mode on/off 1 1 byte or High Volume Auto Relock on/off 2 1 byte 0x00 = OFF, 0xFF = ON default is 0x00 or OFF Auto Relock time 3 1 byte 10 to 180 seconds default is 30 seconds...
Page 7
Yale Assure Lock ® ® Electronic Interconnected Push Button ® Installation and Programming Instructions (YRC216) Inside Outside of Door of Door 4" Touchscreen Shown - 5.5" Available Before you begin Network Module (Optional) DOWNLOAD THE BILT APP for step-by-step installation instructions &...
Page 8
Before You Begin Template Network Module (Optional) 1/8" 3/32" 1/8" 1" 2-1/8" 4-1/2" (114) 1-3/8" (35mm) Min to 1-3/4" (44.5mm) Max YRL EMICL PBINSTL FUL Rev B...
Page 9
Mark Door Reference Lines EXISTING 2-3/8" or 2-3/4" Backset Template YRL EMICL PBINSTL FUL Rev B...
Page 10
Preparing Door (if necessary) Template 4" 5.5" 2-3/8" Ø2-1/8" Ø1" 2-3/4" Drill holes 1/2 way thru door then complete from other side to prevent splitting. YRL EMICL PBINSTL FUL Rev B...
Page 11
Installing Strike Plates 7-16 / 8-32 x 1" UNCWS Frame 1" Dia. x 1"Deep Frame Inside of Door 1" Dia. x 1/2"Deep Door Frame YRL EMICL PBINSTL FUL Rev B...
Page 12
Determining Handing The hand of a door is determined from the secure side of the door. The term "secure" means the side from which you initially unlock and enter. Left Hand “ ”, Hinges Left. Left Hand Reverse " ", Hinges Left. Open Inward.
Page 13
Changing Handing (if necessary) 4" Left Hand to 4" Right Hand Shown 4-24 x 1/4" PPHMS DO NOT TAMPER WITH OR LOOSEN E-CLIP AND ITS ASSEMBLY DO NOT LOOSEN THESE 6 SCREWS OR REMOVE COVER YRL EMICL PBINSTL FUL Rev B...
Page 15
Lockset Handing Configurations For 5.5" For 5.5" For 4" 4" Right Hand For 4" 4" Left Hand Test Lever and Thumbturn After handing is changed, check that lever and thumbturn rotate freely. YRL EMICL PBINSTL FUL Rev B...
Page 16
Installing Fire Cups Inside of Door Both Fire Cups and a marked Latchbolt must be used to qualify for listing. YRL EMICL PBINSTL FUL Rev B...
Page 18
Installing Deadbolt Latch & Latchbolt 7-16 / 8-32 x 1" UNCWS Inside of Door Bolt must be in retracted (unlocked) position before installing. Ensure arrow stamped on deadbolt Choose latchbolt based on backset. (2-3/8" or 2-3/4") Curved edge of latchbolt faces direction door closes.
Page 19
Installing Exterior Deadbolt M6x55 PPHMS Inside of Door YRL EMICL PBINSTL FUL Rev B...
Page 20
Installing Lock Chassis 10-32 x 1-1/2" PPHMS Inside of Door YRL EMICL PBINSTL FUL Rev B...
Page 21
Securing Back Plate to Door #6-32 x 1/2" POHMS Inside of Door Drill two pilot holes Ø1/8" x 1/2" deep Two #6-32 x 1/2" POHMS screws must be used to qualify for listing. YRL EMICL PBINSTL FUL Rev B...
Page 22
Testing Deadbolt & Latchbolt Operation Outside of Door YRL EMICL PBINSTL FUL Rev B...
Page 23
Attaching the Cable Assembly Test that cables are securely connected. Inside of Door Cable must be routed as shown to avoid interference with movement of lock. YRL EMICL PBINSTL FUL Rev B...
Page 24
Installing Interior Lock Orientation must match. Do not fasten lock to back plate until properly fitted. Inside of Door Turn thumbturn to adjust slot orientation. YRL EMICL PBINSTL FUL Rev B...
Page 25
Installing Interior Lock continued 10-32 x 5/8" POHMS 6-32 x 1" PPHMS Inside of Door DO NOT LOOSEN THIS SCREW YRL EMICL PBINSTL FUL Rev B...
Page 26
Installing Interior Lever Inside of Door " SNAP " Inside of Door Pull lever to ensure it is secure. YRL EMICL PBINSTL FUL Rev B...
Page 27
Testing Final Latchbolt Operation Inside of Door Outside of Door YRL EMICL PBINSTL FUL Rev B...
Page 29
Testing Final Deadbolt Operation If testing fails, go back to beginning of Step 11 and check installation. YRL EMICL PBINSTL FUL Rev B...
Page 30
Installing Optional Network Module DO NOT install network module with batteries in unit. Damage may occur. Installing Batteries & Cover Tighten screw to replace cover. Bolt must be in retracted (unlocked) position before installing batteries. YRL EMICL PBINSTL FUL Rev B...
Page 31
Handing the Lock AFTER installing batteries and cover AFTER a factory reset, create Master code. See 1 of Programming Instructions. After entering the Master code: Press Advanced Lock Settings Press to Select Press Handing the Lock Press to Select Press to complete Lock will cycle motor to complete handing.
Page 32
Hardware Troubleshooting Cycle lock in both the locked and unlocked positions. If problems are found: Bolt will not extend and motor is grinding a. Enter your Master code. b. With the bolt retracted, press menu Option 3 for Advanced Lock Settings. c.
Page 33
Changing Lock: Replacing Cylinder 1. To remove cylinder: A. Remove keypad from door. B. Remove rubber gasket. C. Remove two screws holding plastic guide in place. D. Remove plastic guide. E. Remove screw with washer holding cylinder in place (visible after removing plastic guide).
Page 34
Programming Instructions Low Battery Warning- Flashes RED Lock-out Mode- Keypad Flashes Interior Lock Privacy Mode Button Keypad Master Code must be created before any further programming. Max User Codes = 250 with Z-Wave Plus or ZigBee network module Max User Codes = 25 without network module or with iM1 network module Max User Codes - 12 with Bluetooth YRL EMICL PBINSTL FUL Rev B...
Page 35
Creating Master Code Creating a Master Code must be performed upon installation or after resetting the lock to factory default. Programming and use of lock is not possible until this step has been successfully completed. Press Press Press Enter 4-8 digit Master Code.
Page 36
Creating User Codes Master code must be created first. *Max user codes = 250 with Z-Wave Plus or ZigBee network module Max user codes = 25 without network module or with iM1 network module Max user codes - 12 with Bluetooth Enter Master code Press...
Page 37
Unlocking Door with Code Enter PIN Press "Unlock" Code Chart Duplicate if necessary PIN Code Management (With Network Module - Up to 250 Users) User Type User Name PIN Code Master User User User User User User User User User User User User...
Page 38
Resetting Lock to Factory Default Interior Lock When resetting the lock, all user codes, including the Master code*, are deleted. All (4" Shown) programming features are reset to original default settings (see below). 1. Remove the battery cover and batteries. 2.
Page 39
Definitions All Code Lockout Mode: This feature is enabled by the Master code. When enabled, it restricts all user (except Master) code access. When attempting to enter a code while the unit is in Lockout, the keypad flashes 8 times and the lock beeps 3 times as well.
Page 40
Feature Programming Through Menu Mode Using Master code* 1. Enter 4-8 digit master code* followed by key. 2. Enter digit corresponding to the function to be performed followed by the key. *The Master code must be registered prior to any other programming of the lock. Note: After Master code is entered, lock will automatically hand itself.
Page 41
Programming Troubleshooting Symptom Suggested Action • Press each keypad button for response when pressed. • Check batteries are installed and oriented correctly (polarity) Lock does not respond – in the battery case. door is open and • Check batteries are in good condition; replace batteries* accessible.
Page 43