Download Print this page
Assa Abloy Yale Real Living Assure Lock YRD226 Installation And Programming Instructions

Assa Abloy Yale Real Living Assure Lock YRD226 Installation And Programming Instructions

Touchscreen deadbolt
Hide thumbs Also See for Yale Real Living Assure Lock YRD226:

Advertisement

Quick Links

Yale Assure Lock
®
®
Touchscreen Deadbolt
®
Installation and Programming Instructions
(
YRD
226/YRD426)
Optional
Network Module
Before you begin
DOWNLOAD
THE BILT APP
for step-by-step installation
instructions & to register
your product
x3
#8-32 x 5/16"
Machine screws
x4
x2
#7 wood & #8-32
M6x59.5mm
machine x 20mm
Long through bolt
Combination screws
FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN DAMAGE TO
THE PRODUCT AND VOID THE FACTORY WARRANTY
1
P/N
YRL TSINSTL FUL
-
-
Rev F

Advertisement

loading

Summary of Contents for Assa Abloy Yale Real Living Assure Lock YRD226

  • Page 1 Yale Assure Lock ® ® Touchscreen Deadbolt ® Installation and Programming Instructions 226/YRD426) Optional Network Module Before you begin DOWNLOAD THE BILT APP for step-by-step installation instructions & to register your product #8-32 x 5/16" Machine screws #7 wood & #8-32 M6x59.5mm machine x 20mm Long through bolt...
  • Page 2 Preparing Door YRL TSINSTL FUL Rev F...
  • Page 3 Optional Fire Kit Parts For Model ONLY optional Installing Optional Fire Cup optional Inside of Door YRL TSINSTL FUL Rev F...
  • Page 4 Installing Latch & Strike Plate 2-3/8" position d faut 2-3/4" position optional Pull Press Bolt must be in retracted (unlocked) position. Note horizontal orientation of mechanism. YRL TSINSTL FUL Rev F...
  • Page 5 Installing Touchscreen Escutcheon Inside of Door Outside of Door Bolt must be in retracted (unlocked) position. Note horizontal orientation optional of mechanism. YRL TSINSTL FUL Rev F...
  • Page 6 Installing Interior Mounting Plate Loosen screw to remove cover. optional YRL TSINSTL FUL Rev F...
  • Page 7 Attaching the Cable Assembly YRL TSINSTL FUL Rev F...
  • Page 8 Installing Interior Escutcheon YRL TSINSTL FUL Rev F...
  • Page 9 Testing Operation Bolt must be in retracted (unlocked) position before installing batteries. YRL TSINSTL FUL Rev F...
  • Page 10 Testing Operation YRL TSINSTL FUL Rev F...
  • Page 11 Installing Optional Network Module YRL TSINSTL FUL Rev F...
  • Page 12 Installing Batteries & Cover "Welcome to Yale Real Living." Tighten screw to replace cover. Congratulations, you've installed the Yale Assure Lock ® ® Touchscreen Deadbolt ( 226/YRD426)! Continue with Programming Instructions to customize your product. YRL TSINSTL FUL Rev F...
  • Page 13 Programming Instructions Exterior Escutcheon "P" Key (Return to Previous) Interior Escutcheon Low Battery Indicator Lockout Mode Privacy Mode Button Speaker Master Code must be created before any further programming. Max User Codes = 250 with Network Module. Max User Codes = 25 without. YRL TSINSTL FUL Rev F...
  • Page 14 Creating Master Code Creating a Master Code must be performed upon installation or after resetting the lock to factory default. Programming and use of lock is not possible until this step has been successfully completed. "Register Master Code. Press the gear key to continue."...
  • Page 15 Creating User Codes Master code must be created first. *Max user codes = 250 with Network Module. Max user codes = 25 without. "Menu Mode, enter number, press the gear key to continue." Enter Master code Press Press Press Enter 4-8 digit code Press Press...
  • Page 16 Unlocking Door with Code Enter Code Press Code Chart Duplicate if necessary PIN Code Management (With Network Module - Up to 250 Users) User Type User Name User # PIN Code Master User ___ User ___ User ___ User ___ User ___ User ___ User ___...
  • Page 17 Resetting Lock to Factory Default Interior Escutcheon When lock is reset to factory defaults all user codes (including the Master code*) are deleted and all programming features are reset to original default settings (see below). 1. Remove the battery cover and batteries. 2.
  • Page 18 Factory Settings Settings Factory Setting Registration required* Master Code Automatic Re-lock Disabled Automatic Re-lock Time 30 Seconds Escape Return Mode (Model 620 only) Disabled Inside Indicator Light Disabled (Off) Language Setting English Disabled Lockout Mode One Touch Locking Enabled Privacy Setting Disabled Shutdown Time 60 Seconds...
  • Page 19 Definitions All Code Lockout Mode: This feature is enabled by the Master code. When enabled, it restricts all user (except Master) code access. When attempting to enter a code while the unit is in Lockout, the locked padlock will appear on the screen. Automatic Re-lock Time: After a successful code entry and the unit unlocks, it will automatically re-lock after thirty (30) seconds.
  • Page 20 Model 226 Feature Programming Through Menu Mode Using Master code* 1. Touch screen with back of hand or palm to activate. 2. Enter 4-8 digit master code* followed by key. Lock Response: "Menu mode, enter number, press key to continue." 3.
  • Page 21 Model 620 Feature Programming Through Menu Mode Using Master code* 1. Touch screen with back of hand or palm to activate. 2. Enter 4-8 digit master code* followed by key. Lock Response: "Menu mode, enter number, press key to continue." 3.
  • Page 22 Programming Troubleshooting Symptom Suggested Action Touchscreen becomes active when pressed w/whole hand. Use a larger area of the hand or fingers and verify contact Lock does not respond – with at least 3 areas. door is open and If touchscreen numbers are visible, check to see if they accessible.
  • Page 23 Hardware Troubleshooting Cycle lock in both the locked and unlocked positions. If problems are found: Bolt will not deadlock a. Check for sufficient clearance of the bolt within the strike-side jamb. Correct this by increasing the depth of the pocket for the bolt. b.
  • Page 24 Cet appareillage numérique de la classe A répond à toutes les exigences de l'interférence canadienne causant des règlements d'équipement. Product Support Tel 1-855-213-5841 • www.yalehome.com Yale Locks & Hardware is a division of Yale Security Inc., an ASSA ABLOY Group company. Yale® , Yale Real Living® and Assure Lock® are registered trademarks of Yale Security Inc., an ASSA ABLOY Group company.
  • Page 25 ® ® Yale Real Living Z -Wave Plus Module ® Installation and Programming Instructions ® Installing the Z -Wave Plus Module IMPORTANT: the batteries must be removed prior to removing and/or inserting the network module: • Remove battery cover and batteries. •...
  • Page 26 Product Support Tel 800.810.WIRE (9473) • www.yalelocks.com Yale Locks & Hardware is a division of Yale Security Inc., an ASSA ABLOY Group company. Copyright © 2016, Yale Security Inc., an ASSA ABLOY Group company.
  • Page 27 Yale Locks YRD426 Z-Wave Plus System Integrators Guide Yale Assure Deadbolt Lock Document Revision: 1 January 14, 2019...
  • Page 28: Table Of Contents

    Contents Yale Z-Wave Plus Product Info ........................3 Supported Command Classes ........................3 Association Table ............................ 3 Notifications Table ..........................4 Configurable Parameters ......................... 6...
  • Page 29: Yale Z-Wave Plus Product Info

    Yale Z-Wave Plus Product Info Manufacturer ID: Assa Abloy (0x0129) Z-Wave Device Type: Door Lock Keypad Z-Wave Role Type: Listening Sleeping Slave (LSS) Product ID: 0x1000 Product Type ID: 0x8002 – YRD426-ZW2 (Touch Screen Deadbolt) Supported Command Classes Command Class Z-Wave Plus Info...
  • Page 30: Notifications Table

    Notifications Table Alarm Alarm Reports Alarm Level Description type 0x00 Master code was changed at keypad Master Code changed. 0xFB Master code was changed over RF 0x70 0x(01-max User added User added. Alarm level = user slot number users) 0x(01-max User deleted 0x21 User was deleted.
  • Page 31 Where Alarm level represents user slot number Alarm generated in response to add user RF cmd. This alarm is not generated when attempting to add Duplicate Pin-code 0x (01-max 0x71 duplicate pin at the keypad. The lock simply denies it error users) and plays the “Denied”.
  • Page 32: Configurable Parameters

    Configurable Parameters Configuration Parameter Size Description Parameters Number Level control, 1 = High Volume, 2 = Low Volume, 3 = Silent mode on/off 1 1 byte Silent. Default is 2 or Low Volume Auto Relock on/off 2 1 byte 0x00 = OFF, 0xFF = ON default is 0x00 or OFF Auto Relock time 3 1 byte 10 to 180 seconds default is 30 seconds...

This manual is also suitable for: