Installation

a

Prepare Door

Prepare door for function holes, size, and location according to A8258
door marker template, if not already prepped.
b

Install Lock

1. Verify strike location according to template. Clean out door pocket
and door edge of debris.
2. Ensure handing of lock and door match. Slide lock into door. (Figure 6)
3. Temporarily hand tighten two (2) lock screws (#12 x 1-1/4"
wood screws, or #12-24x 1/2" machine screws).
Note:
Keep door open until installation is complete.
c

Install Outside Trim

1. Verify lock is in unlocked state (control hub slot should be vertical).
Also, verify indicator is in vacant/unlocked position.
2. Align trim posts with diagonal holes in door, be sure lever is horizontal. Slide outside escutcheon
assembly through lock body from outside door face. (Figure 7)
Note:
If indicator is used on outside, align indicator spindle with control hub.
d

Install Inside Trim

1. Slide spindle into lockbody hub. (Figure 8)
2. Slide adapter and plate assembly over spindle.
3. Secure with two (2) #8-32 x 5/8" screws.
4. For Studio Collection levers only, use trim bushing over adapter plate.
5. Verify lock is in unlocked state (turn outside lever to ensure).
Also, Verify indicator is in vacant/unlocked position.
6. Align escutcheon over adapter and install inside
escutcheon assembly onto inside door face.
Notes:
7. Through-bolt inside escutcheon to outside
escutcheon with two (2) #8-32 x 2-1/4" screws.
8. Install inside lever on adapter plate.
Secure with set screw.
Note:
Screw heads should be visible on inside escutcheon.
1-800-727-5477 • www.sargentlock.com
Copyright© 2019, 2020 SARGENT Manufacturing Company. All rights reserved. Reproduction in whole
or in part without the express written permission of SARGENT Manufacturing Company is prohibited.
If indicator is used on inside, align indicator
spindle with control hub.
Inside of door
Lock
Screws
Lock
Figure 6
Outside Escutcheon Assembly
Inside
#8-32 x 2-1/4" screw
Escutcheon
Assembly
Studio
Collection
Trim
Bushing
#8-32 x
5/8" screws
Adapter Plate
Spindle
Figure 8
4
Outside
of door
RH door
shown
Figure 7
Set
Lever
screw
#8-32 x
2-1/4"
screw
A8260C 03/20