MASTERTIG
Feature
Range of output (110 V)
Power factor, λ
Efficiency, ƞ
Idle power
Operating temperature range
Storage temperature range
EMC class
Degree of protection
External dimensions
Weight without accessories
Arc-on signal for relay
Voltage supply for cooling unit
Recommended generator power
(min)
Wireless communication type:
- Control panels MTP23X, MTP33X,
(2
MTP35X
- Remote controls HR45, FR45
Wired communication type
Arc striking voltage
Stick electrode diameters
Standards
NO: These devices are not allowed to be used within a 20 km radius of the centre of Ny-Ålesund at Svalbard, Nor-
2)
way. This restriction applies to any 2-32 GHz transmitter operation.
© Kemppi
Description
TIG
MMA
230 V, MMA 180 A /
27.2 V
230 V, MMA 120 A /
24.8 V
TIG
LxWxH
U
cu
S
gen
Transmitter frequency
and power
(2
Remote
CAN BUS
ø mm
MasterTig 235ACDC, 325DC, 335ACDC
235ACDC GM
Value
3 A / 1 V ... 130 A / 24 V
10 A / 1 V ... 85 A / 35 V
0.99
84 %
20 W
-20...+40 °C
-20...+60 °C
A
IP23S
544 x 205 x 443 mm
19.1 kg
24 V / 50 mA
220...240 V (cooler not sup-
ported in 110 V)
8 kVA
2.4 GHz Bluetooth, 2400-
2483.5 MHz, 10 dBm
Analog
Kemppi Remote-Bus
5...11 kV
1.6...5.0 mm
IEC 60974-1,-3,-10
IEC 61000-3-12
GB 15579.1
59/73
Operating manual - EN
235ACDC GM
(VRD locked on)
3 A / 1 V ... 130 A / 24 V
10 A / 1 V ... 85 A / 35 V
0.99
84 %
20 W
-20...+40 °C
-20...+60 °C
A
IP23S
544 x 205 x 443 mm
19.1 kg
24 V / 50 mA
240 V (cooler not supported in
110 V)
8 kVA
2.4 GHz Bluetooth, 2400-
2483.5 MHz, 10 dBm
Analog
Kemppi Remote-Bus
5...11 kV
1.6...5.0 mm
IEC 60974-1,-3,-10
IEC 61000-3-12
AS 60974.1-2006
GB 15579.1
1920900 / 1921