3.3.4 Start & stop sequence view
The parameters diagram view makes base parameter identification and setting easy. From pre-gas time to post-gas
time and everything in between, you can quickly select and adjust the needed parameter value.
To adjust parameters:
1.
Go to the Start & stop sequence view.
2.
Turn the control knob (1) to browse through the parameters.
3.
Select a parameter for adjusting by pressing the control knob button (1).
4.
Adjust the parameter by turning the control knob (1).
5.
Close the parameter setting by pressing the control knob (1).
Adjustable parameters in all welding modes:
Trigger logic: 2T / 4T / 4T LOG / 4T LOG + Minilog (Default = 2T)
Welding mode: Continuous / Spot / MicroTack
Welding current: Default = 50 A.
Adjustable parameters in continuous welding:
Pre gas: 0.0 s ... 10.0 s, Auto, 0.1 s step (Default = Auto)
Search arc: OFF / 5 % ... 90 %, step 1 % (Default = OFF)
Upslope: OFF / 0.1 s ... 5.0 s, 0.1 s step (Default = 0.0 s)
Hot start level: -80 % ... 100 %, 1 % step (Default = OFF, 0 %)
Hot start time: 0.1 s ... 5.0 s, 0.1 s step (Default = 1.2 s)
>> This is not available with 4T trigger logic.
Minilog level: -99 % ... 125 %, 1 % step (Default = OFF, 0 %)
Downslope: OFF / 0.1 s ... 15.0 s (Default = 0.1 s)