OPTISWIRL 5080
Measuring accuracy
Reference conditions
Factory calibration conditions
Accuracy
Liquids
Gases and steam
Process temperature effect
on K-factor
Operating conditions
Temperature
Process temperature
Ambient temperature
Pressure
Medium pressure
Maximum static pressure
Media properties
Density
Viscosity
Reynold's number
04/2020 - 4005615602 - MA OPTISWIRL 5080 R02 en
Medium: Clear water
Process & ambient temperature: +20...+30°C / +68...+86°F
Relative humidity: 50...90%
Supply voltage at mA output: 24 ± 0.5 VDC
±0.5% of measured value (Re ≥ 30000)
±1.0% of measured value (20000 < Re < 30000)
±2.0% of measured value (10000 < Re < 20000)
±1.0% of measured value (Re ≥ 20000)
±2.0% of measured value (10000 < Re < 20000)
There is an effect on the reference K-factor due to a diameter change of the flow tube
bore with temperature. The effect is -0.3% of flow rate per +55°C / +100°F increase in
temperature. The flowmeter will automatically recompute a flowing K-factor when
process temperature is entered in the database fluid definition.
+150...+430°C / +302...+806°F
Non-Ex: -20...+80°C / -4...+176°F
Non-Ex:
Non-Ex:
Non-Ex:
Ex: depending on type of protection and temperature class
Ex:
Ex:
Ex:
ATEX intrinsically safe: T
a
ATEX flameproof: T
= -20...+80°C
a
FM intrinsically safe: T
= 80°C
a
FM explosion-proof: T
= -40...+85°C
a
IECEx intrinsically safe: T
IECEx flameproof: T
= -20...+80°C
a
Note: When operating at ambient temperatures below -29°C / -20°F, it is important to
maintain a minimum loop voltage of 15.75 VDC to maintain remote configurator
communications capability.
Designed to withstand pressure within ANSI/ASME B16.5 Class 150, 300, 600, 900 or
1500 flange ratings and metric EN 1092-1, PN16, PN40, PN63, PN100 or PN160 flange
ratings.
103.4 barg / 1500 psig / 10340 kPa or that imposed by flange rating.
Taken into consideration when sizing.
< 10 cP
> 10000
www.krohne.com
= -40...+80°C
= -40...+80°C
a
TECHNICAL DATA