KROHNE OPTISWIRL 5080 Handbook page 65

Vortex flowmeter for high temperature applications
Hide thumbs Also See for OPTISWIRL 5080:
Table of Contents

Advertisement

OPTISWIRL 5080
Cross reference
2 Total
2 Tuning
Menu level 3
3 VisEGU
3 mA Out -> Status
3 mA Out ->Value
3 FlwMap
3 FlwURV
3 SetLFCI
3 Bas Den
3 Custom
3 Label
3 Offset
3 Cal mA
3 DenEGU
3 SetDig
3 Velcty
3 Name
3 FldTyp (Read Only)
3TotGrd
3 Coms
3 KCor
3 K Ref / 4 K Ref
3 Lfci (Read Only) / 3
CalLFCI
3 Display
3 BoreSch
3 TotNet
3 Fail
3 Pipe
3 FlwMap
3 FlwURV
04/2020 - 4005615602 - MA OPTISWIRL 5080 R02 en
Parameter
Total Units
Totals Operations
Tuning
Abs Viscosity Unit
AO Status
AO Value
AO/PV Map
AO/PV URV
Auto LFCI
Base Density
Custom K Bias
Custom PV Label
Custom PV Offset
D/A Trim
Density Units
Digital Output
Flow Velocity
Fluid Name
Fluid Type
Grand Total
HART Output
K Corrected
K Factor
LFCI
Local Display
Mating Pipe
Net Total
O/P Alarm Code
Piping
PO/PV Map
PO/PV URV
www.krohne.com
Explanation
Path to configuring the totals parameters.
Path to viewing, starting, stopping, or clearing the totalizers.
Path to configuring the tuning parameters.
Select the viscosity unit from the picklist provided.
Shows the AO status
Shows the AO value
Shows whether the PV is mapped to "Volume Flow", "Mass
Flow", "BVolFlow" or "Velocity".
Shows the AO/PV URV
Procedure for the flowmeter to automatically set the LFCI.
In "1 Setup", enter the base density in the density unit
specified. This is only used to calculate the base volumes.
In "1 Setup", enter the custom K-factor (with sign in percent).
In "1 Status", shows the custom K-Factor.
Enter the label for your custom PV unit.
Enter any offset.
Procedure to trim the 4 and 20 mA output values of the
flowmeter to match the output of a plant standard
measurement device.
In "Detailed Setup", select the density unit from the picklist
provided.
In "Review", shows the density units.
Path to configuring the digital output.
Shows the flow velocity value.
In "1 Setup", enter the name of the fluid.
In "Review", shows the fluid name.
In "1 Setup" the fluid type will be shown.
In "Process Variables", shows the grand total.
In "1 Setup", path to configuring the grand total mapping and
units.
Path to configuring the HART output.
In "1 Status" shows the K corrected value.
In "1 Status", shows the K-Factor value. In "1 Setup", enter the
K-Factor.
In the "1 Setup", shows the low flow cut-in value.
In "1 Cal/Tst", the LFCI can be automatically calibrated.
Path to configuring the local display.
In "1 Setup", select the type of mating pipe from the picklist
provided.
In "Process Variables", shows the net total.
In "Detailed Setup", path to configuring the net total mapping
and units.
In "1 Setup", configure the output to go fully upscale or
downscale if a failure occurs.
Path to configuring the piping parameters.
Shows whether the PV is mapped to "Volume Flow", "Mass
Flow", "BVolFlow" or "Velocity".
Shows the PO/PV URV.
OPERATION
5
65