System Power Force On

Jumper JP1 allows you to enable or
disable the Force Power On function. If
enabled, system power will always stay
on. If disabled (the normal setting), the
user needs to press the power button
to power on the system.
3rd PWR Supply Fail Detect
The system can notify you in the event
of a power supply failure. This feature
assumes that three power supply
units are installed in the chassis, with
one acting as a backup. If you only
have one or two power supply units
installed, you should disable this (the
default setting) with J3P to prevent
false alarms.
SAS Controller Enable/
Disable
JPS1 enables or disables the AIC
9140W Adaptec SAS controller. See
the table on the right for jumper set-
tings. The default setting is enabled.
Chapter 5: Advanced Serverboard Setup
System Power Force On
Jumper Settings
Jumper Setting
Closed
Open
3rd PWR Supply Fail Detect
Jumper Settings (J3P)
Jumper Setting
Closed
Open
Note: this jumper should be disabled on the
6024H-32R/6024H-32.

SAS Controller Enable/Disable

Jumper Settings (JPS1)
Jumper Setting
Pins 1-2
Pins 2-3
5-21
(JP1)
Defi nition
Force On
Disabled
Defi nition
Enabled
Disabled
Defi nition
Enabled
Disabled