Jlan1 Enable/Disable; Jlan2 Enable/Disable; I C Bus To Pci; System Power Force On - Supero SUPERSERVER 5015M-MF User Manual

High-end single processor mini 1u rackmount server
Table of Contents

Advertisement

S
S
UPER
ERVER 5015M-MR(+)/5015M-MF(+) User's Manual

JLAN1 Enable/Disable

Change the setting of jumper JPL1 to
enable or disable the JLAN1 Ethernet
port on the motherboard. See the
table on the right for jumper settings.
The default setting is enabled.

JLAN2 Enable/Disable

Change the setting of jumper JPL2 to
enable or disable the JLAN2 Ethernet
port on the motherboard. See the
table on the right for jumper settings.
The default setting is enabled.
I
2
C Bus to PCI
Jumpers JI
2
C1 and JI
to connect the PCI/PCI-X slots to the
System Management (I
default setting is "Open" to disable the
connection. Both jumpers must be set
to the same setting. See the table on
the right for jumper settings.

System Power Force On

Jumper JPF allows you to enable or
disable the Force-Power-On function.
If enabled, system power will always
stay on. If disabled (the normal set-
ting), the user needs to press the power
button to power on the system.
2
C2 allow you
2
C) Bus. The
5-18
JLAN1 Enable/Disable
Jumper Settings (JPL1)
Jumper Setting
Defi nition
Open
Enabled
Pins 2-3
Disabled
JLAN2 Enable/Disable
Jumper Settings (JPL2)
Jumper Setting
Defi nition
Pins 1-2
Enabled
Pins 2-3
Disabled
I
2
C Bus to PCI
Jumper Settings
(JI
2
C1/JI
2
C2)
Jumper Setting
Defi nition
Closed
Enabled
Open
Disabled
System Power Force On
Jumper Settings
(JPF)
Jumper Setting
Defi nition
Closed
Force On
Open
Disabled