Connect Cables

WARNING:
fixture below 5°C (41°F). When the fixture has been stored or
transported in cold temperatures, allow it to warm to room
temperature for a minimum of 1 hour before applying power.
Applying power to a cold fixture will cause damage to the
fixture and void ETC warranty.
1. Connect one RJ45 data cable for data-in and one for data-thru, as
needed. Use the strain relief at the bottom of the fixture to support
the data cables (see image in
Leave a loop of data cable between the connector and the strain relief
to ensure that the connection point is not stressed.
• To order an RJ45-to-socket XLR adapter, use ETC part number
W6538.
• To order an RJ45-to-plug XLR adapter, use ETC part number
W6539.
2. If this is the last fixture in the line, terminate the fixture with a
120 Ohm resistor. Please contact your ETC customer service
representative to purchase ETC part number N4086. See
ETC Technical Services on page 2
3. Connect the fixture to a non-dimmable power source.
DMX Dimming
• When using DMX over Cat5, use Cat5e or better.
• Cable distance for full DMX daisy chain must not exceed 300 m
(1000 ft).
• Up to 32 fixtures can be connected together into a daisy chain.
• The fixture cannot be controlled via Ethernet protocols and should
not be directly connected to an Ethernet system.