Rigging

WARNING:
clamp for proper and secure installation before hanging the luminaire.
AVERTISSEMENT :
luminaire, vérifiez chaque crochet et chaque porteuse pour une installation
correcte et en sécurité.
1.
Lift the luminaire to the installation location. We recommend that two people lift the
luminaire.
2.
Secure the luminaire in place using the previously installed truss clamps or other
installation hardware. Secure the attachment hardware in place by tightening the
hardware (wing bolt or other hardware), ensuring the luminaire is securely installed and
supported to the truss.
Note:
rigging. When the luminaire is mounted in an overhead rigged position, you must also
secure it in place using a safety cable that can hold at least ten times the weight of the
luminaire. A suitable safety cable is available from ETC (part number 7060A1022).
Contact ETC for additional details.
3.
Attach a safety cable to the luminaire.
a.
Loop one end of the safety cable around the enclosure handle and attach the clip
onto the cable.
b.
Loop the other end of the cable around the truss or pipe structure, then secure the clip
onto the cable.

Connect Data and Power

Connect DMX-512

ETC recommends Belden 9729 or equivalent 2-pole twisted, shielded wire. The connectors must
be XLR 5-pin female (DMX IN) and XLR 5-pin male (DMX THRU). Following best practices for
DMX, a maximum of 32 DMX devices may be connected in any one DMX data run when
installed in a daisy-chain fashion. See
cable specifications.
XLR Pinout
ETC recommends using the following standard pinout when preparing DMX cable (Belden 9729
or equivalent) with an XLR connector. The second data pair in the recommended cable type is
not used by the Relevé Spot luminaire and should be capped off and tied back for future service.
DMX Thru Receptacle
Push
5
4
*XLR pins viewed from the
outside
Installation
RISK OF INJURY! Check each clamp mounting rail and truss
DANGER DE BLESSURE ! Avant d'accrocher le
The installation must follow local codes and standard practices for overhead
DMX-512 Pinout for 5-pin XLR (EIA-485)
Pin #
1
2
1
3
2
3
4
5
DMX512-A on page 10
Use
Common (shield)
Data - (typically black wire)
Data + (typically white wire)
unused
unused
for details on DMX connector and
DMX Input Receptacle
1
2
3
*XLR pins viewed from the
outside
5
4
23