Table 27 FHFL dual-width GPU installation guidelines
Number of GPUs
1
2
3
4
Table 28 FHFL single-width GPU installation guidelines
Number of GPUs
1
2
3
4
5
Table 29 HHHL GPU installation guidelines
Number of GPUs
1
2
3
4
5
6
7
8
9
10
14
Power supplies
To avoid damage to hardware, use only H3C approved power supplies.
•
The server supports 1+1 power supply redundancy.
•
•
The power supplies installed on the server must be the same model. If they differ in model,
HDM would raise an alarm.
The power supplies are hot swappable.
•
The system provides an overtemperature mechanism for power supplies. The power supplies
•
automatically turn off when they encounter an overtemperature situation and automatically turn
on when the overtemperature situation is removed.
Recommended GPU installation locations
Slot 5
Slots 2 and 5
Slots 2, 5, and 7
Slots 11, 12, 13, and 14
Recommended GPU installation locations
Slot 5
Slots 2 and 5
Slots 2, 5, and 7
Slots 1, 2, 4, and 5
Slots 1, 2, 4, 5, and 7
Recommended GPU installation locations
Slot 5
Slots 2 and 5
Slots 2, 5, and 7
Slots 2, 3, 5, and 6
Slots 2, 3, 4, 5, and 6
Slots 1, 2, 3, 4, 5, and 6
Slots 1, 2, 3, 4, 5, 6, and 7
Slots 1, 2, 3, 4, 5, 6, 7, and 8
Slots 1, 2, 3, 4, 5, 6, 7, 8, and 9
Slots 1, 2, 3, 4, 5, 6, 7, 8, 9, and 10
Slots 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 12, 13, 14, and 15