H3C UniServer R4700 G5 Server
Processor Installation Quick Start
New H3C Technologies Co., Ltd.
http://www.h3c.com
Document version: 6W100-20210712

Advertisement

loading
Need help?

Need help?

Do you have a question about the UniServer R4700 and is the answer not in the manual?

Questions and answers

Summary of Contents for H3C UniServer R4700

  • Page 1 H3C UniServer R4700 G5 Server Processor Installation Quick Start New H3C Technologies Co., Ltd. http://www.h3c.com Document version: 6W100-20210712...
  • Page 2 The information in this document is subject to change without notice. All contents in this document, including statements, information, and recommendations, are believed to be accurate, but they are presented without warranty of any kind, express or implied. H3C shall not be liable for technical or editorial errors or omissions contained herein.
  • Page 3 Preface This preface includes the following topics about the documentation: • Audience. • Conventions. • Documentation feedback. Audience This documentation is intended for: • Network planners. • Field technical support and servicing engineers. • Server administrators working with the Server. Conventions The following information describes the conventions used in the documentation.
  • Page 4 Symbols Convention Description An alert that calls attention to important information that if not understood or followed WARNING! can result in personal injury. An alert that calls attention to important information that if not understood or followed CAUTION: can result in data loss, data corruption, or damage to hardware or software. An alert that calls attention to essential information.
  • Page 5 Documentation feedback You can e-mail your comments about product documentation to info@h3c.com. We appreciate your comments.
  • Page 6: Table Of Contents

    Content Overview ···························································································································································· 1 Processor kit ······················································································································································ 1 Preparing for installation ···································································································································· 1 Installing the processor ······································································································································ 2 Installing DIMMs················································································································································· 8 Starting the server ·············································································································································· 9...
  • Page 7: Overview

    The information in this document might differ from your product if it contains custom configuration options or features. The figures in this document are for illustration only. Processor kit The processor kit for an H3C UniServer R4700 G5 server includes the following components: • Processor •...
  • Page 8: Installing The Processor

    Figure1-1 Removing the access panel Remove the chassis air baffle. As shown in Figure1-2, lift the air baffle up to remove it from the chassis. Figure1-2 Removing the chassis air baffle Installing the processor CAUTION: • The server can use two or four processors. •...
  • Page 9 CAUTION: When you remove the protective cover from the heatsink, be careful not to touch the thermal grease on the heatsink. Figure1-3 Removing the protective cover Install the retaining bracket onto the heatsink. a. As shown in Figure1-4, align the alignment triangle on the retaining bracket with the cut-off corner of the heatsink.
  • Page 10 Figure1-5 Ejector lever status on the retaining bracket Install the processor onto the retaining bracket. CAUTION: To avoid damage to a processor, always hold the processor by the edges. Never touch the gold contacts on the processor bottom. a. Tilt the processor, align the small triangle on the processor with the alignment triangle in the retaining bracket, and insert one edge of the processor into the retaining bracket.
  • Page 11 Figure1-7 Locking the processor Remove the processor socket cover. CAUTION: • Be careful not to touch the pins on the processor socket when you wear ESD gloves to remove the processor socket cover. • The pins on the processor socket are very fragile. Never touch the pins. Any damage to them might require system board replacement.
  • Page 12 Figure1-8 Removing the processor socket cover Install the heatsink onto the server. a. Align the alignment triangle on the retaining bracket with the cut-off corner of the processor socket and the pin holes in the heatsink with the guide pins on the processor socket. Lower down the heatsink on the processor socket.
  • Page 13 Figure1-10 Locking the heatsink c. Use a T30 Torx screwdriver to fasten the four captive screws on the heatsink. CAUTION: The screwdriver torque is in the range of 6 to 12 in-lb. As a best practice, use a torque of 8 in-lb to avoid poor contact of the processor or damage to the pins on the processor socket.
  • Page 14: Installing Dimms

    Installing DIMMs After you install a new processor, install DIMMs for it. For the DIMM installation guidelines, see the server user guide. To install a DIMM: Open the retaining clips of the DIMM slot. Figure1-12 Opening the retaining clips of the DIMM slot Align the notch on the DIMM bottom edge with the key on the DIMM slot.
  • Page 15: Starting The Server

    Figure1-13 Installing a DIMM Starting the server Install the chassis air baffle on the server. Lower down the chassis air baffle and place it into the chassis. Figure1-14 Installing the chassis air baffle Install the access panel. a. Place the access panel on top of the server chassis, with the guide pin in the chassis aligned with the pin hole in the locking lever area.
  • Page 16 Figure1-15 Installing the access panel Install the server into the rack. Connect power cords for the server. Power on the server.