Disassembling The Plug-In Connecting Cable For Tubular Drives Dia. 45 And Dia. 58; Installation; Assembling The Drive - Becker P4-30 Assembly And Operating Instructions Manual

Tubular drive with integrated 915.3 mhz radio receiver for zip systems
Table of Contents

Advertisement

Disassembling the plug-in connecting cable for tubular drives dia. 45 and dia. 58

Caution
Prior to disassembly, the power supply to the connecting cable must be disconnected.
Insert a suitable flathead screwdriver right into the recess of the locating latch, so that the latch releases the locating lug from the
plug.
Now you can pull out the connecting cable along with the flathead screwdriver.
dia. 45 and dia. 58
A = locating latch

Assembling the drive

Attention
To connect the drive to the driven part, solely mechanical accessory components made by
the drive manufacturer from the current product catalogue may be used.
Prior to mounting, the fitter must ensure that the masonry and the system being motorised are sufficiently robust (drive torque plus
weight of the shading solution).
Caution
Electrical connections may only be carried out by a qualified electrician. Prior to assembly,
the power supply must be disconnected and secured. Please give the enclosed connection
information to the responsible electrical contractor.
These drives cannot be operated with conventional switching elements (switches, timers
and the like).
8
1.
A
2.

Installation

Advertisement

Table of Contents
loading

This manual is also suitable for:

R40-17C18a

Table of Contents