Becker P3-30 Assembly And Operating Instructions Manual

Roller shutter and sun protection drives with mechanical limit switch

Advertisement

Quick Links

P3-30...L120-11
Model: M04
Assembly and Operating Instructions
en
Roller shutter and sun protection drives with
mechanical limit switch
Important information for:
• Fitters / • Electricians / • Users
Please forward accordingly!
These instructions must be kept safe for future reference.
2010 300 332 0m     12/09/2022    
Becker-Antriebe GmbH
Friedrich-Ebert-Straße 2-4
35764 Sinn/Germany
www.becker-antriebe.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the P3-30 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Becker P3-30

  • Page 1 P3-30...L120-11 Model: M04 Assembly and Operating Instructions Roller shutter and sun protection drives with mechanical limit switch Important information for: • Fitters / • Electricians / • Users Please forward accordingly! These instructions must be kept safe for future reference.
  • Page 2: Table Of Contents

    Table of contents General .................................... 3 Warranty .....................................  3 Safety instructions ................................ 4 Instructions for the user.............................. 4 Instructions for installation and commissioning........................ 4 Intended use .................................. 5 Assembling and disassembling the plug-in connecting cable.................... 6 Assembly ....................................  6 Setting the limit positions.............................. 9 Information for the electrician .............................
  • Page 3: General

    General These tubular drives are high-quality products with the following features: • For use with roller shutters • For use with sunblinds • Easy limit switch setting on the drive • Compatible with all of the drive manufacturer's control units for roller shutters and sunblinds •...
  • Page 4: Safety Instructions

    Safety instructions The following safety instructions and warnings are intended to avert hazards and to prevent property damage and personal injury. Instructions for the user General information • The drive must be disconnected from its power source during cleaning and maintenance and when re- placing parts.
  • Page 5: Intended Use

    • If the drive is used for shading solutions in a specially marked area (e.g., escape routes, hazard zones, safety areas), compliance with all applicable regulations and standards must be ensured. • Once the drive has been installed, the fitter must mark the used tubular drive in the “Technical data” chapter and make a note of the installation position.
  • Page 6: Assembling And Disassembling The Plug-In Connecting Cable

    Assembling and disassembling the plug-in connecting cable Caution The power supply to the connecting cable must be disconnected prior to assembly/disas- sembly. Assembling the plug-in connecting cable Ø35/Ø45/Ø58 Insert the dead connecting cable into the drive head until the locating lug clicks into place in the drive. If necessary, use a suitable flathead screwdriver to assist with insertion.
  • Page 7 Caution Electrical connections may only be carried out by a qualified electrician. Prior to assembly, the power supply must be disconnected and secured. Please give the enclosed connection information to the responsible electrical contractor. Calculate the space required at the side (M) by measuring the drive head (1) and wall bracket (2). The clear dimension of the box (X) minus the space required at the side (M) and idler (G) gives the length (L) of the barrel: L=X-M-G.
  • Page 8 For round shafts: Measure the lug of the thrust ring (X, Y). Then notch the tube on the motor side, so the lug of the thrust ring can also be pushed into the shaft. There must be no play between the lug of the thrust ring and the shaft.
  • Page 9: Setting The Limit Positions

    Setting the limit positions Upper limit position Lower limit position Lower limit position Upper limit position Setting the lower limit position 1. Before the shading solution is fixed to the barrel, let the drive run DOWN until it switches off automatically. 2.
  • Page 10: Information For The Electrician

    This product must be handed over to a collection point for electrical and electronic equipment at the end of its service life. The packaging material must be disposed of properly. Maintenance These drives are maintenance-free. Technical data dia. 35 Tubular drive P3-30 P5-20 P5-30 P9-16 P13-9 Model...
  • Page 11: Technical Data Dia. 45

    Technical data dia. 45 Tubular drive R7-85 R8-17 R12-11 R12-17 R15-17 R20-11 R20-17 Model Type Rated torque [Nm] Output speed [rpm] Limit switch range 38 revolutions Supply voltage 230 V AC / 50 Hz Connected load [W] Rated current consumption 1.18 0.45 0.47...
  • Page 12: Technical Data Dia. 58

    Technical data dia. 58 Tubular drive L44-14 L50-11 L50-17 L60-11 L60-17 Model Type Rated torque [Nm] Output speed [rpm] Limit switch range 36 revolutions Supply voltage 230 V AC / 50 Hz Connected load [W] Rated current consumption [A] 1.20 1.05 1.40 1.20 1.75 Operating mode S2 4 min Degree of protection IP 44...
  • Page 13: Sample Wiring Diagrams

    Sample wiring diagrams Control via a single switch/button Central, group and individual control using Centronic UnitControl UC42 Central Control unit Mains 230 V / 50 Hz Central cable 230 V / 50 Hz (connection to further control units) Group 230 V / 50 Hz Individual Individual 230 V / 50 Hz...
  • Page 14: Declaration Of Conformity

    Declaration of conformity For UK-Markets: The Declaration of Conformity can be provided upon request from Becker Motors Ltd., or can be downloaded on www.beckermo- tors.co.uk. 14 - en...

Table of Contents