Changing direction of rotation via master transmitter
It is only possible to change the direction of rotation if no limit position has been set.
Press the UP or DOWN button
▻ The shading solution runs in the desired direction.
► The running direction is OK.
If the shading solution runs in the wrong direction, the running direction must be changed. Proceed as follows:

Intelligent installation management

Limit position status indicator
A brief stopping and restarting indicates that no limit position has been set in that direction of movement.
Completion of installation following automatic setting of limit positions
The drive saves the limit position permanently once the upper limit position is reached 3 times in succession. Installation is then
complete. If the limit position is set above a point, this is stored permanently.

Setting the limit positions

The limit positions can only be set with the master transmitter. The shutter direction must
be correct. When setting the limit positions, the tubular drive runs in dead-man mode and
limit position status indicator. The lower limit position must always be set first. If the tubu-
lar drive switches off prematurely while opening or closing, due to an obstruction, the ob-
struction can be cleared by opening or closing the screen and removing the obstruction.
The desired limit position can be set by opening or closing again.
There are several ways to set the limit positions:

• Lower point to upper point

• Lower point to upper stop

• Auto install
The limit position becomes fixed after the tubular drive has turned off automatically in the desired position three times.
Lower point to upper point
There is no shading solution length adjustment with this limit position setting.
14
First press the programming button and, within the next 3 seconds, press both the UP
and DOWN buttons for 3 seconds.
► The tubular drive acknowledges.
Check the running direction again.
Close to the desired lower limit position.
Press the programming button and, within 3 seconds, also press the DOWN button
and hold the two buttons down.
▻ The tubular drive acknowledges.
Then open to the desired upper limit position.
Press the programming button and, within 3 seconds, also press the UP button and
hold the two buttons down.
▻ The tubular drive acknowledges.
► The limit positions are now set.