Lower point to upper stop
Deleting the limit positions
Attention
When both or individual limit positions are deleted, all the other set functions (intermediate
position I, intermediate position II, obstacle detection, run times) are deleted as well.
Once set, the limit positions can only be deleted with the master transmitter. Deleted limit
positions are displayed on the limit position status indicator.
Deleting individual limit positions
Deleting both limit positions
Any additional functions that may have been set are deleted at the same time, or are reset
to the factory default settings.
Close to the desired lower limit position.
Press the programming button and, within 3 seconds, also press the DOWN button
and hold the two buttons down.
▻ The tubular drive acknowledges.
Then open as far as the permanent stop.
▻ The tubular drive switches off automatically.
► The limit positions are now set.
Open/close to the limit position to be deleted.
Press the programming button and, within the next 3 seconds, press the STOP button
at the same time and hold the two buttons down for 10 seconds.
▻ The tubular drive acknowledges.
► The limit position is now deleted.
Open/close the shading solution to a point between the limit positions.
Press the programming button and, within the next 3 seconds, press the STOP button
at the same time and hold the two buttons down for 10 seconds.
▻ The tubular drive acknowledges.
► The limit positions are now deleted.
15