21— Spring Seat
22— Spring
23— Spool
47— Filter
17— Cover
18— Cover
20— Socket Bolt
1— Body
7— Bolt
16— Bolt
rii : 14 mm
r—emm: 34+4.9 tsl-m
( 3.5+0.5 kgf-m, 25+3.6 lbf-ft )
Assemble Flow Combiner Valve
(EX3OUR-2, EX4OUR-2)
1. Insert spool (32), shim (36), and spring (31) into
body (1).
Tighten plug (30) into body (1).
31— Spring
32— Spool
1— Body
30— Plug
UPPERSTRUCTURE / Control Valve
Assemble Flow Combiner Valve (EX2OUR-2)
1. Sandwich spool (23) between wooden plates.
Clamp in a vise. Install spring seat (21) and
spring (22) onto the spool.
2. Insert spool (23) into body (1). Install cover (17)
using bolt (16).
NOTE: Be sure to apply a film of hydraulic oil onto
spool (23) before inserting.
T50302-06-002
The illustration shows the flow
combiner valve section of the
EX3OUR-2 control valve.
W506-02-05-001
3. Install cover (18) onto body (1) using bolt (16).
: 4 mm
5 mm
r
--.04: 7.3 to 10 rsi-rn
( 0.74 to 1.02 kgf-m, 5.4 to 7.4 lbf-ft )
2.9 to 4.9 Nl-rn
( 0.3 to 0.5 kgf-m, 2.2 to 3.6 lbf-ft )
W02-04-18