Power Connections; 380-2D Power Connections - Rice Lake Revolution Synergy Series Technical Manual

Digital weight indicators
Table of Contents

Advertisement

2.9

Power Connections

Power is connected to the power supply and the CPU board through the power harness.
2.9.1

380-2D Power Connections

The 380 Synergy Indicator is powered by 4 C-Cell Batteries or an optional 12 V adapter (PN 206433). When the adapter is
inserted into the power jack, indicator power is disconnected from the battery holders and batteries no longer drain. The Power
adapter does not charge the batteries.
NOTE: Optional power adapter (PN 206433) is the only external power source allowed to be used.
NOTE: Ensure that battery covers are screwed finger tight. If covers are not fully screwed on, the indicator will not function.
Connector
Pin
CN1
1
2
3
4
Table 2-8. CN1 Alkaline Battery Pin Assignments (Power Supply)
Black wire to GND
Black Jumper Wire
Red wire to CN1
Pin 1
Table 2-8
Figure 2-12. 380-2D Battery Cell Wiring