10.1.4 Operation of communication setting

Channel and driver assignment operation
1
The operation method for the channel and communication driver assignment is described here.
In this section, the case for changing the computer link connection (Communication driver: [AJ71QC24,
MELDAS C6*]) to CPU direct connection (Communication driver: [A/QnA/QCPU, QJ71C24]) is described.
(In the present example, [Communication Settings] is not downloaded.)
Before starting operation
(1) Restarting the GOT
(2) Setting retention
After Communication Setting is executed, the GOT automatically restarts.
If the project data is downloaded, GOT starts monitoring the communication
device after restarting.
Before starting the operation, check for safe conditions.
Once being established, [Channel-Driver assign] is retained until [Communication
Settings] is updated.
Install communication driver [A/QnA/
1
QCPU, QJ71C24] to the GOT
[Communication Settings] with
AJ71QC24, MELDAS C6*.
([Communication Settings] is not
downloaded from drawing software.)
After installing the communication driver,
touch the
CH-Driver assign
[Communication Settings].
The screen shown on the left is
2
displayed.
Touch the
Change
Touch the communication driver
3
installed to the GOT ([A/QnA/QCPU,
QJ71C24]).
10.1 Communication Setting
10.1.4 Operation of communication setting
button in
button.
10 - 5
9
10
11
12
13
14
15
16