Refill the chiller (first design)
• Demineralized water
• Pouring can
• Screwdriver (Torx-25)
NOTE
For information on the prescribed maintenance materials, see
maintenance materials on page
CAUTION
Wear specified gloves when you refill the chiller to protect your skin.
IMPORTANT
Only refill one liter of demineralized water when you get a warning, when you use more the
liquid can spill and damage the machine.
Procedure
1. On the operator panel, tap on the [System] icon on the right.
2. Tap on [Power management].
3. Tap on [Power off].
The system shuts down.
4. When the system has shut down, pull to open the cover under the roll winder.
NOTE
There are 2 types of the cover under the roll winder. In the new design you can access
the power switch through an opening in the cover.
First design
5. Switch the power switch to the 'off' position.