4.18 Flap and piping projection

Unhindered passage of the workpieces at the folder/pick-up folder requires
that the maximum projections of piping, flap and material thickness (see dia-
gram) not exceed the permissible limit. For the maximum allowable piping
strip widths for the respective sewing equipment (E-No.), refer to the Equip-
ment Sheets of the 745-35-10.
Fig. 28: Flap and piping projection
(1) - Folder
(2) - Flap projection max. 20 mm
(3) - Flap
(4) - Piping strip
(5) - Piping projection max. 20 mm/40 mm
Setting the sewing depth of the flap
Fig. 29: Setting the sewing depth of the flap (1)
(1) - Flap stop
To set the sewing depth of the flap:
1. Remove the flap stop (1).
38
Operating Instructions 745-35-10 B/745-35-10 F - 00.0 - 04/2017
a
b
NA
(6) - Guide plate at the folder
NA: Seam clearance
a, b: Material passage at the folder
(2) - Hexagon bolt
Operation