Programming
 The display switches to Flap scan.
Fig. 85: Activating the flap (1)
Symbols
To activate the flap:
1. Press the desired button.
2. Enter the desired value using the numeric keypad.
3. Confirm with OK.
Operating Instructions 745-35-10 B/745-35-10 F - 00.0 - 04/2017
Activating the flap
Meaning
Activate fixed seam length
Set sewing length
Not available unless Activate sewing length has been selected
Activate flap scan with 1 light barrier
Set maximum flap length
Not available unless Activate flap scan has been selected
Activate automatic flap scan left
• Light barrier must be activated in the machine configuration  p. 142