Programming
Loading process test
The display switches to Loading process test.
Fig. 130: Loading process test
The sewing material is fed through the sewing path without sewing including
all functions stored in the seam program.
The loading process test is designed to check if the flaps and piping strips
are transported correctly through the sewing path.
Information
To monitor the transport path of the sewing material, we recommend that
you reduce the insertion speed prior to the loading process test ( p. 125)
.
To perform a loading process test:
1. Press the Loading process test
button.
The machine boots up.
2. Perform a reference run.
The insertion mode is active.
3. Insert the sewing material.
4. Press the pedal to close the transport clamp.
The display shows the message
.
5. Press the right pedal.
The loading process is completed without sewing by performing
pedal strokes.
6. To exit the test: access the menu again and press the OFF button.
166
Operating Instructions 745-35-10 B/745-35-10 F - 00.0 - 04/2017