Notes On Setting Up The Communication Connection; Required Open Ports - Siemens VersiCharge 8EM1310-F.0 Series Operating Instructions Manual

Ac wallbox - erk
Table of Contents

Advertisement

5.2

Notes on setting up the communication connection

5.2.1

Required open ports

These open ports are required for communication with the Siemens Device Management,
logging server and OCPP server:
Domain name
versicharge.emobility.siemens.cloud
versichargesgeuprod.blob.core.windows.net
data.logentries.com
eu.data.logs.insight.rapid7.com
s-b184b487ff5c4c75a.server.transfer.eu-cent­
ral-1.amazonaws.com
siemens.com
pool.ntp.org
siemens.pool.ntp.org
Multiple (e.g. dns.opendns.com)
dns.opendns.com
*.store.core.windows.net
NOTE
If you use an OCPP server, you need additional open ports. You can find this information in
the documentation for the OCPP server.
VersiCharge AC Wallbox Operating Instructions ERK
Operating Instructions, 08/2023, A5E51549696-AC
5.2 Notes on setting up the communication connection
Ports
Application layer
protocol
443, 9019
HTTPS, WSS
443
HTTPS
443
HTTPS
443
HTTPS
22
SFTP
N/A
ICMP
123
UDP
123
UDP
53
UDP and TCP
53
DNS
443
HTTPS
Commissioning
Usage
Registration, upgrade requests, Web­
Socket communication
Firmware updates
Logging
Logging
Secondary server for firmware
updates
Determine if the Wallbox has a net­
work connection
NTP server
NTP server
Accessing the Domain Name Server
DNS
Firmware updates